1 easy and advanced modes, 2 viewing captured data, 3 preferences – Teledyne LeCroy SierraNet M408 User Manual Ver.1.40 User Manual

Page 36: 4 port status, 8 infusion

Advertising
background image

Teledyne LeCroy

InFusion

34

 

SierraNet M408 User Manual

1.7.1

Easy and Advanced Modes

Click on the Trigger/Filter Setting icon 

 located in the Trigger/Filter Settings pane 

under the main application toolbar to select Easy or Advanced mode.

In Easy Mode, select the Filter tab to select Capture EverythingFilter in Selected 
Patterns 
or Filter Out Selected Patterns. You can opt to Always Filter Out Idles or Ports 
and Truncate Payload in DWord(s). For Filter in Selected Patterns, select a Pattern from 
the left pane. You can exclude patterns and frames. You can do this by dragging patterns 
from the Patterns Library pane into the Active pane. You can use different patterns for 
pre‐trigger and post‐trigger.

In Easy Mode, on the Trigger tab, select the trigger type. Select a Pattern from the left 
pane as explained above.

Change the Analyzer settings if necessary. Change the port Speed if necessary. 

See 

“Trigger and Filter Settings in Easy Mode” on page 59.

Use Advanced Mode only after you become familiar with the hardware and software and 
have special needs. To start working with the protocol analyzer and software. For more 
information on Advanced Mode refer to 

“Advanced Mode (User‐Defined)” on page 140.

1.7.2

Viewing Captured Data

After data capture, the captured data is in the Viewer, see 

“Display Manipulation” on 

page 147. 

You can display the same data in:

Spreadsheet View: Shows Protocol Fields and Frames by time.

Frame Inspector View: Shows detail information about packet highlighted in 
Spreadsheet or Packet views.

Traffic Summary View: The Traffic Summary View for each captured signal can 
be viewed. It displays errors for the whole trace or for a selected range. You can 
show grid lines, select rows and modify columns.

Data View: The 

Data

View displays information in Hexadecimal and ASCII format.

1.7.3

Preferences

For special work, you can use the Preferences menu to configure Software Settings, Port 
Alias, Address Alias and Display Settings. (See

“Preferences” on page 178

.)

1.7.4

Port Status

You can display an overview of the active ports by clicking the buttons at the bottom right 
of the main window (see 

“Ports Status” on page 167

). 

1.8 InFusion

The Teledyne LeCroy InFusion™ Error Injector and Traffic Modifier is an error injector and 
traffic modification tool that allows you to verify real‐world fault handling for SierraFC 
systems (see 

“InFusion” on page 191

).

Advertising