Summit T3‐16 PCI Express Multi‐Lane Protocol Analyzer User Manual
19
Using Probes
Teledyne LeCroy
3.8.11
Connecting the Probe Data Cable
x8 recordings require one cable. To connect a single Interposer data cable, connect the
probe data cable to the Interposer card at [7:0]. Connect Side A of the probe cable to the
Upstream [7:0] port on the Analyzer, and connect Side B of the probe cable to the
Downstream [7:0] port.
x16 recordings require two cables. Connect the second probe data cable to the Interposer
card at [15:8]. Connect Side A of the second probe cable to the Upstream [15:8] port on
the Analyzer, and connect Side B of the second probe cable to the Downstream [15:8]
port.
3.9 Using
Probes
3.9.1
Example: Connecting the Summit T3-16 Analyzer to the Device Under Test
Using a Gen2 MidBus Probe
Components
Figure 3.13: 1 or 2 iPass Y-cable
Figure 3.14: Gen2 MidBus Probe Pod