Setting Up the Summit Z3‐16 Exerciser using an Ethernet Connection

  Teledyne LeCroy

3. Connect the USB port to a USB port on the host machine using a USB cable. Go to 

Step 4 below.

4. Turn on the power to the host machine or the PCI Express Test Platform 16x2.5GT/s / 

16x5.0GT/s / 16x8.0GT/s. 

Note:

At power‐on, the Exerciser initializes itself in approximately five seconds and 

performs an exhaustive self‐diagnostic that lasts about forty seconds. 

5. Follow the Microsoft

®

 

Windows

®

 

on‐screen Plug‐and‐Play instructions for the 

automatic installation of the Exerciser as a USB device on your analyzing host 
machine. (The required USB drivers are installed on your system during software 
installation)

6. Click Finish when you see the message that says “Windows has finished installing 

the software that your new hardware requires” and the file has been installed in 
your host machine. 

7. Do not change from USB to Ethernet, or back, without power cycling the Exerciser.

3.3

Setting Up the Summit Z3-16 Exerciser using an Ethernet
Connection

To connect the Exerciser using USB (see

 “Setting Up the Summit Z3‐16 Exerciser using a 

USB Connection” on page 24)

.

1. Connect the Exerciser to a 100‐volt to 240‐volt, 50 Hz to 60 Hz, 120 W power outlet 

using the provided AC power adapter, or to the DC power connector if using the PCI 
Express Test Platform. 

2. Plug the Exerciser into either the host machine or the PCI Express Test Platform.

Note:

The AC power adapter is capable of supporting supply voltages between 100 volts 

and 240 volts, 50 Hz or 60 Hz, thus supporting all known supply voltages around the 
world.

3. Connect the Ethernet cable between the Ethernet port on the side of the Exerciser 

and an Ethernet port (hub, switch or wall) in your local network. 

4. Turn on the power to the host machine or the PCI Express Test Platform 16x2.5GT/s / 

16x5.0GT/s / 16x8.0GT/s. 

Note:

At power‐on, the Exerciser initializes itself in approximately five seconds and 

performs an exhaustive self‐diagnostic that lasts about forty seconds.

5. After you have installed the PETracer application software, perform the following 

procedure to connect to a Summit Z3‐16 Exerciser in a local network. 