Vanguard EZCT-S2 User Manual

Page 8

Advertising
background image

EZCT S2 USER’S MANUAL

REV 3

4

1.3

Technical Specifications

Table 1. EZCT S2 Technical Specifications

TYPE

Portable current transformer test set

PHYSICAL SPECIFICATIONS

16.8”W x 12.6”H x 12”D (42.7 cm x 32 cm x 26.9 cm); Weight: 55 lbs (25 kg)

INPUT POWER

100 – 120 Vac or 200 – 240 Vac (factory pre-set), 50 Hz/60 Hz

MEASUREMENT METHOD

ANSI/IEEE C57.12.90, IEC 60044-1 and ANSI/IEEE C57.13.1 standards

TEST OUTPUT VOLTAGES

0 – 50 Vac @ 10A max, 0 – 250 Vac @ 10A max
0 – 500 Vac @ 5A max, 0 – 1500 Vac @ 1.2A max

VOLTAGE READING RANGE

0 – 2,200 Vac; Accuracy: ±1.0% of reading, ±1 volt

CURRENT READING RANGE

0 – 10A; Accuracy: ±1.0% of reading, ±0.02A

CURRENT-RATIO RANGE

0.8 – 999: 0.1%, 1000 – 1999: 0.3%, 2000 – 5000: 1%

PHASE ANGLE

MEASUREMENT

0 - 360 degrees; Accuracy: ±1.0 degree

DISPLAY

Back-lit LCD Screen (20 characters by 4 lines); viewable in bright sunlight
and low-light levels

PRINTER

Built-in 4.5-inch wide thermal printer

COMPUTER INTERFACES

One RS-232C port (115k baud), one USB port

PC SOFTWARE

Windows

®

XP/Vista-based CT Analysis software is included with purchase

price

INTERNAL TEST RECORD

STORAGE

Stores 140 test records. Each test record may contain up to 10 sets of
excitation, resistance and ratio data

INTERNAL TEST PLAN

STORAGE

Stores 128 test plans. Each test plan can store 10 excitation test voltage and
current settings

SAFETY

Designed to meet UL 61010A-1 and CAN/CSA C22.2 No. 1010.1-92
standards

ENVIRONMENT

Operating: -10˚ to 50˚ C (15˚F to +122˚ F); Storage: -30˚ C to 70˚ C (-22˚F to
+158˚ F)

CABLES

Two 20-foot X cable sets, One 35-foot H cable set, power cord, One cable-
carrying duffel bag

WARRANTY

One year on parts and labor

NOTE

The above specifications are valid at nominal operating voltage and at a
temperature of 25

°C (77°F). Specifications may change without prior notice.

Advertising