Programming functions: default settings – Warner Electric CBPC-3590 User Manual

Page 11

Advertising
background image

Warner Electric • 800-825-9050

P-291-1 • 819-0526 11

q

2. Re-tighten encoder bracket securely.

q

3 . Proceed to step 1 of the start-up procedure,

page 9 to recalibrate the system .

Note: If in doubt about encoder positioning, refer to
new encoder installation procedure, page 6.

If unit has problems such as “windmilling” program
default needed, do the following steps:

q

a. Press the RUN/PGM key on the keypad.

q

b. Enter 1, 0, 0, 0 and then press the down arrow

repeatedly until the end display reads: “t8.rdy”.

q

c. Press the arrow right button.

q

d. Press the RUN/PGM key.

q

e . Proceed to step 1 of the start-up procedure

on page 9 to recalibrate the system .

This completes the installation and set-up of the
CBPC-3590 control. Close and latch the control
securely .

As the controller has been designed as an improved
version of the CBC1500-AHFC with additional
features and improved performance and reliability,
programming of the various parameters should only
be accomplished by qualified personnel .

To Enter the programming mode, follow the steps
below:

Open the controller front cover for access to the
keypad/display. Press the RUN PGM key on the
keypad/display

Display will show LOC. 0

Then press 1, 0, 0, 0
Display will show LOC. 1000


This has now placed you in the programming mode
where various parameters can be changed by using
the down arrow key to increment through the various
parameters .

Programming Functions:

Default Settings

Default

Press

Display

Value

Function

h xxx

--

Home Position

bd. xx

--

Brake Distance, PPR

↓ bdAue . 3

3

Cycles Averaged

↓ cc. 0.5000

0.5000

Count Correction

dP. oFF

oFF

Decimal Point

↓ FrSt. oN

oN

Front Panel Reset

↓ PLoc. oFF

oFF

Panel Lock

↓ CrEt. oFF

oFF

Count Retention

↓ ArSt. oN

oN

Auto Reset

↓ o1. 0.20

0.20

Start Signal, ms

↓ o2. 0.01

0.01

Early Warning, ms

↓ o3. 0.20

0.20

Stop Signal, ms

↓ o4. 0.10

0.10

Zero Speed, ms

↓ o5. 0.05

0.05

Zero Speed + delay 1, ms

↓ o6. 0.05

0.05

Zero Speed + delay 2, ms

↓ o8. LatCH

LatCH

Batch Auto Reset

↓ d1. 0.10

0.10

Delay 1, ms

↓ d2. 0.01

0.01

Delay 2, ms

↓ 05P .25

.25

Zero Speed Window, sec

↓ 5 -.-.-.-.-.-. -.-.-.-.-.-.

Start Release

↓ L - .- .- .- .- .- . - .- .- .- .- .- .

Move Preset Release

↓ E - .- .- .- .- .- . - .- .- .- .- .- .

Early Warning Release

↓ r - .- .- .- .- .- . - .- .- .- .- .- .

Reset Release

↓ bd. OFF

OFF

Baud Rate

↓ Par. None

None

Parity

PFr. 80

80

Output Frequency, Hz.

cPr. 90

90

Clutch Output Percentage

bPr. 75

75

Brake Output Percentage

JPr. 40

40

Jog Output Percentage

cBt 15

15

Clutch Boost Percentage **

bBt 40

40

Brake Boost Percentage **

↓ Id.no. xxx

xxx

Unit Number (Up to 3 digits)

t0. rdy

rdy

Keyboard test

t1 . rdy

rdy

RAM test

t2 . rdy

rdy

Inputs test

t3 . rdy

rdy

Outputs test

t4 . rdy

rdy

Display test

t5. rdy

rdy

Memory test

t6. rdy

rdy

Date Code

t7 . rdy

rdy

Serial Test

t8. rdy

rdy

Reset Default Program

** Only when the OEX add-on board is installed in the CBPC-3590 are

these two functions active and operational for programming.