Oven service procedures, Temperature control programming procedure – XLT XD-9007A (ELEC Oven Version – B1, AVI Hood Version – B) User Manual

Page 19

Advertising
background image

19

Technical Support US: 888-443-2751

Technical Support INTL: 316-943-2751

Temperature Control Programming Procedure

OVEN SERVICE PROCEDURES

Configuration Key Functions
<FUNC> =

The new setting of the selected parameter is stored

and the display advances to the next parameter. This

is required between each parameter.

=

Increases the setting of the selected parameter.

=

Decrease the setting of the selected parameter.

1. Open V101 switch for Basic Configuration (Figure 1)

Turn main switch to the off position

Remove instrument from its case

Open Switch V101

Re-insert the instrument back in its case.

Turn main switch to the on position

2. Basic Configurations

Using the configuration keys scroll thru parameter codes

changing them to match (Figure 2)

After P12 _._._._. Will appear

3. Close V101 switch after Basic Configuration (Figure 1)

Remove instrument from its case

Close Switch V101

Re-insert the instrument back in its case.

Error 400 will appear press and hold the and to clear

000 will appear

4. Advanced Configurations Procedure

Using the configuration keys scroll thru parameter codes

Changing them to match (Figure 3)

On the first pass thru change nnn to 311 to unlock the

advanced configuration

Scroll thru the parameter codes again and change the nnn to 5

this locks the advanced configuration

Scroll thru the parameter codes again and verify nnn is ON

SP

260˚C/500˚F

nnn

311/5

AL

315˚C/600˚F

HSA

.1

Pb

4.0

ti

5.0

td

.00

1P

30

C

2

rL

204˚C/400˚F

rH

310˚C/590˚F

OLH

100

tOL

InF

Read the entire instruction before programming.

P1

2˚C/10˚F

P2

0

P3

315˚C/600˚F

P4

r

P5

1

P6

H.A.

P7

d

P8

OFF

P9

0

P10

100

P11

311

P12

7

Figure 2

Advertising