5 chassis installation, 1 airflow, Hassis – IEI Integration KINO-9652 v1.11 User Manual
Page 109: Nstallation, Figure 5-13: cf card setup jumper location, Table 5-8: cf card setup jumper settings
Advertising

KINO-9652 Mini-ITX SBC
Page 87
The CF Card Setup jumper sets the CF Type I card or CF Type II cards as either the slave
device or the master device. CF Card Setup jumper settings are shown in Table 5-8.
CF Card Setup
Description
Open
Slave Default
Closed
Master
Table 5-8: CF Card Setup Jumper Settings
The CF Card Setup jumper location is shown in Figure 5-13.
Figure 5-13: CF Card Setup Jumper Location
5.5 Chassis Installation
5.5.1 Airflow
WARNING:
Airflow is critical to the cooling of the CPU and other onboard
components. The chassis in which the KINO-9652 must have air vents
to allow cool air to move into the system and hot air to move out.
Advertising