3 automatic mode, Figure 8-11: smart fan setting – pwm mode – IEI Integration IMBA-Q454 v1.01 User Manual
Page 185

IMBA-Q454-R10 User Manual
Page 185
Figure 8-11: Smart Fan Setting – PWM Mode
8.4.3.3 Automatic Mode
In the Automatic Mode, the user can set the temperature that decides the fan activity. The
following value can be set (
978H
Figure 8-12):
Fan Start (°C): the fan starts when the temperature reaches the set value
Fan Off (°C): the fan turns off when the temperature reaches the set value
Full Speed (°C): the fan runs at full speed when the temperature reaches the
set value
Start PWM Value (0~127): the initial PWM value when the fan starts
Slope (PWM Value (add/°C): the PWM value added per degree Celsius (°C)
of temperature increase when the fan start running
To set the value, double click the number and enter a new value. Click apply or ok when
finish.