ECN-780-Q67 Em b e d d e d S ys te m

P a g e 77

 Tem p eratu re o f Start [75]

WARNING:

Setting this value too high may cause the fan to rotate at full speed only

when the CPU is at a very high temperature and therefore cause the

system to be damaged.

The Temperature of Start option can only be set if the CPU Smart Fan control option is

set to Auto Mode. When the CPU Temperature is higher than Temperature of Start, the

fan will be rotate at full speed. To set a value, select the Temperature of Start option and

enter a decimal number between 0 and 127. The temperature range is specified below.

 Minimum Value: 0°C

 Maximum Value: 127°C

 Tem p eratu re o f Off [80]

WARNING:

Setting this value too high may cause the fan to speed up only when

the CPU is at a very high temperature and therefore cause the system

to be damaged.

The Temperature of Off option can only be set if the CPU Smart Fan control option is

set to Auto Mode. When the CPU Temperature is higher than Temperature of Off, the

fan will be speed up. To set a value, select the Temperature of Off option and enter a

decimal number between 0 and 127. The temperature range is specified below.

 Minimum Value: 0°C

 Maximum Value: 127°C

 Start PWM [30]