IEI Integration UPC-12A_GM45 v2.10 User Manual

Page 37

Advertising
background image

UPC-12A/GM45 Panel PC

Page 25

ATX Mode

UPS Mode

Battery Mode

Battery Only

NOT able to turn on by the power

button.*

Turn on by the power button.*

External DC Only Able to turn on by the power

button.

Able to turn on by the power

button.

System

Booting

Battery +

External DC

Able to turn on by the power

button.

Able to turn on by the power

button.

Battery Only

Turn off the system by soft

shutdown, power button or

battery dead

Turn off the system by soft

shutdown, power button or

battery dead

External DC Only Turn off the system by soft

shutdown or power button

Turn off the system by soft

shutdown or power button

System

Shut

Down

Battery +

External DC

Turn off the system by soft

shutdown or power button

Turn off the system by soft

shutdown or power button

Battery Only

Remain power on until the

battery is dead**

Remain power on until the

battery is dead**

External DC Only Turn off automatically when the

power is disconnected.

Turn off automatically when the

power is disconnected.

DC Power

Fail

Battery +

External DC

Remain power on until the

battery is dead**

Remain power on until the

battery is dead**

*

*

Under the UPS mode, the system can not be turned on when only with battery connected.

** The UPS terminal switch does not work under ATX power mode (no matter the battery is

connected or not).

Table 2-3: ATX Power Mode

Advertising