4.5.2 JP4: COM1 and COM2 Pin-9 Signal Select Jumper Settings

The COM1 and COM2 pin-9 signal can be selected as 12V, 5V or Ring.

JP4 Description

Short 1, 3

COM1 pin-9 is 12V output

Short 3, 5

COM1 pin-9 is 5V output

Short 5, 7

COM1 pin-9 is 5V output

Short 7, 9

COM1 pin-9 is RI input

Default

Short 2, 4

COM2 pin-9 is 12V output

Short 4, 6

COM2 pin-9 is 5V output

Short 6, 8

COM2 pin-9 is 5V output

Short 8, 10

COM2 pin-9 is RI input

Default

Table 4-2: COM1 and COM2 Pin-9 Signal Select Jumper Settings

4.5.3 JP5: COM2 Mode Select Jumper Settings

The COM2 can be selected as RS-232 or RS-485.

JP5 Description

Short 1-2

RS-232

Default

Short 2-3

RS-485

Table 4-3: COM2 Mode Select Jumper Settings