Lincoln Electric IMt793 MIG-PAK 15 User Manual

Page 40

Advertising
background image

40

M20141

A

ELECTRICAL SYMBOLS PER E1537

CAVITY NUMBERING SEQUENCE

( COMPONENT SIDE OF BOARD )

539

541

213

GUN TRIGGER

THERMOSTAT

208

5K

WIRE SPEED

R2

(W)

(B)

N.C.

209

214

211

WINDING

24V

AUXILIARY

FAN MOTOR

H2

541

204

203

209

208

539

213

214

1 2 3 4

LATCH

5

6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

GAS

SOLENOID

CONTROL P.C. BOARD J1

CR1

H1

H2

LS1

H2

H2

D3

204

204

204

203

203

203

C1

40V

203

204

GUN CABLE

CONDUCTOR

BLOCK

TO

WORK

T1

N.B.

N.A.

X1

202

X2

S2

SELECTOR

SWITCH

OUTPUT

CHOKE

X4

X5

+

H1

N.A. DIODES D1,D3,D5 & D7 ARE MOUNTED

ON THE OUTSIDE HEATSINK.

D1

D5

D2

D6

D7

D4

D8

X3

X6

204

204

203

203

H2

N.O.

208V/60HZ

H3

230V/60HZ

H3

TO EARTH GROUND

PER NATIONAL, LOCAL

OR OTHER APPLICABLE

ELECTRICAL CODES.

G

N.D.

N.D.

211

THERMOSTAT

+

-

H1

(230V)

H3

(208V)

LEAD COLOR CODE:

B-BLACK

W-WHITE

(MOUNTED TO

SEC. COIL)

(MOUNTED TO

DIODE HEATSINK)

WIRE

FEED

MOTOR

CIRCUIT

BREAKER

N.B. DIODES D2,D4,D6 & D8 ARE MOUNTED ON THE INSIDE

HEATSINK, WHICH IS CLOSEST TO THE CENTER PANEL.

CASE

GROUNDING

STUD

N.C. COMPONENT VIEWED FROM REAR.

S1

ON-OFF

SWITCH

93,000 f

N.D. BOLTED ALUMINUM CONNECTIONS REQUIRE T12837 JOINT

COMPOUND (DOW CORNING 340) WHEN REATTACHING.

J1

A

N.C.

A

WARNING

HIGH VOLTAGE

can kill

Only qualified persons should install,

Do not operate with covers removed.
Disconnect input power by unplugging

Do not touch electrically live parts

use or service this machine.

power cord before servicing.

CUSTOMER VOLTAGE RECONNECTION FOR DUAL VOLTAGE MACHINE

MACHINES ARE SHIPPED FROM FACTORY CONNECTED FOR 230V AS SHOWN. TO CONNECT WELDER FOR 208V. INPUT,

DISCONNECT WELDER FROM INPUT POWER, REMOVE CASE SIDE, REMOVE LEAD MARKED "H1" FROM CR1. REMOVE TAPE

SECURING H3 LEAD ASSEMBLY TO INPUT CORD AND CONNECT H3 TO CR1. INSULATE UNUSED H1 TERMINAL LEAD FOR

300V WITH ELECTRICAL TAPE AND SECURE TO INPUT CORD. REINSTALL CASE SIDE BEFORE CONNECTING INPUT POWER.

RECONNECTION TO 230V IS REVERSE OF ABOVE PROCEDURE. SEE INSTRUCTION MANUAL FOR DETAILS.

NOTE: This diagram is for reference only. It may not be

accurate for all machines covered by this manual.
The specific diagram for a particular code is pasted
inside the machine on one of the enclosure panels.

NOTA: Ce schéma n'est donné qu'à titre de référence. Il

peut ne pas être exact pour toutes les machines
traitées dans ce manuel. Le schéma particulier
pour un code spécial est collé à l'intérieur de la
machine sur un des panneaux du boîtier.

NOTA: Este diagrama es sólo para referencia. Es posible

que no sea exacto para todas las máquinas que se
mencionan en este manual. El diagrama específico
para su máquina se localiza dentro de la misma, en
uno de los páneles.

Advertising