HYDRAULIC SYSTEM REQUIREMENTS
Refer to the performance charts, below, to properly match your hydraulic system to the H-930 Model winch performance. The
charts consist of :
(1) Line pull (lb.) first layer vs. working pressure (PSI)
(2) Line speed, first layer (FPM) vs. gallons per minute (GPM).
Performance based on a motor displacement of 24 cubic inches with 30 GPM maximum flow rate. See page 17 for motor port
size.
H-930 Performance
30,000 lb. Duty Rating
41:1 Gear Ratio
2
LOW PRESSURE LINES
(.88 I.D. MINIMUM)
HIGH PRESSURE LINES
WINCH MOTOR
HYDRAULIC
LOW PRESSURE LINES
FLUID FILTER
RELIEF VALVE
PUMP
RESERVOIR
FLUID
4 WAY, 3 POSITION
CONTROL VALVE
(SUCTION)
PUMP INLET LINE
VALVE (CYLINDER SPOOL)
(1.31 I.D. MINIMUM)
GALLONS PER MINUTE
20
LINE PULL, LBS., FIRST LAYER
5,000
0
0
20,000
15,000
10,000
30,000
25,000
LINE SPEED, FPM, FIRST LAYER
3,000
WORKING PRESSURE, P.S.I.
2,000
1,000
0
0
10
DYNAMIC
STATIC
5
10
15
30