11

HMI5000P Installation Guide

1010-1014 Rev 01 www.maplesystems.com

clamps and not form a seal with the gasket. Make sure all supplied
mounting clamps are used and that the panel does not flex or bow more
than 0.010 in. to ensure a proper seal.

The HMI should be mounted into a panel with a depth of at least 4 in.
(105 mm). Allow a clearance of at least 1 in. (25 mm) on each side for
mounting hardware. Consider proper clearance for cable connections
when mounting.

NOTE: Cutout dimensions for each particular HMI model are readily
available for download from the Support Center-Dimensional Drawings
section of the Maple Systems website.

The area of the panel or mounting surface where the gasket comes into
contact must be flat and free of scratches, pits, and other features that
prevent the gasket from sealing properly. If the panel or mounting
surface is not uniform, thick, flat, stiff, or smooth enough, then a sealant
such as silicone may be required.

NOTE: Clean and deburr the panel cutout before the HMI is installed.

Warning: The HMI requires a stiff, flat, smooth mounting

surface free of blemishes to seal properly to NEMA 4.
All supplied mounting clamps must be used and the panel cannot
flex more than 0.010”.