When installing the GP unit in a slanted position, the GP unit face should
not incline more than 30°.

When installing the GP unit in a slanted position with an incline more than

30°, the ambient temperature must not exceed 40 °C (104 °F). You may

need to use forced air cooling (fan, A/C) to ensure the ambient operating

temperature is 40°C or less (104 °F or less).

For easier maintenance, operation and improved ventilation, install the GP
unit at least 100 mm (3.94 in.) away from adjacent structures and other
equipment as shown in the following illustration.

The holes on the rear of the GP unit are not correspondent with VESA 75mm
standards. Do not attach the GP unit to the commercial-type VESA arm.



R

RUOHVV

mm

in.

100

3.94

100

3.94

100

3.94

100 3.94

100 3.94

100 3.94

100 3.94