Connecting the dc power cord – Proface GP4600R - 12.1 Standard HMIs with Rear Mounting Options" User Manual
Page 40
Advertising
42
Eng
lis
h
Wiring
1. Connecting the DC Power Cord
Field wiring terminal marking for wire type (75
°C (167 °F) Copper conductors
only)
*1 If the conductor’s end (individual) wires are not twisted correctly, the end
wires may either short against each other or against an electrode.
Power Cord Diameter
0.75 to 2.5 mm
2
(18-13 AWG)
Conductor type
Simple or Stranded Wire
*1
Conductor length
mm
in.
10
0.39
Advertising
This manual is related to the following products: