LT3000 Series Hardware Manual

3-2

3.1 Examples of Particular I/O Connections

3.1.1

Connection to Pulse Motor Amplifier (CW/CCW type)

The following circuit diagrams show examples of connections between the LT and a pulse motor amplifier (in

the case where the transistor can be connected to the amplifier).

„

Output Sink Type

• The circuit of the pulse motor amplifier is illustrated by the DC24V CW and CCW con-

cept. However, the withstand voltage and the operating current of the coupler, which

receives pulse signals, vary by manufacturer. Please contact the amplifier manufacturer

before using.

• The output terminals for LT pulses are the ones that have the signal names OUT0, OUT1,

OUT2, and OUT3. For details of the setting,

please refer to the GP-Pro EX

Reference Manual.

Internal
Circuit

Internal
Circuit

Fuse
2.5A

DC 24V
External
Power supply

+24V

LT

Amplifier (DC24V-capable)

Lead wires
from motor

+

-

DIO

0V

OUT0

OUT3

CW A

CW B

CCW A

CCW B

SEE