Output sink type – Proface LT3300 - 5.7 All-in-One HMI" User Manual

Page 65

Advertising
background image

LT3000 Series Hardware Manual

3-4

3.1.2

Connection to Pulse Motor Amplifier (Clock Up/Down System)

The following circuit diagrams show examples of connections between the LT and a pulse motor amplifier (in

the case where the transistor can be connected to the amplifier).

„

Output Sink Type

• The circuit of the pulse motor amplifier is illustrated by the DC24V clock up/down sys-

tem. However, the withstand voltage and the operating current of the coupler, which

receives pulse signals, vary by manufacturer. Please contact the amplifier manufacturer

before using.

• The output terminals for LT pulses are the ones that have the signal names OUT0, OUT1,

OUT2, and OUT3. For details of the setting,

please refer to the GP-Pro EX

Reference Manual.

• Output signals for switching do not have to be connected to terminals that accommodate

high-speed output, and can be connected to general-purpose terminals (LT-3200 series:

OUT 4 and OUT5, LT-3300 series: OUT4 through OUT15).

Internal
Circuit

Internal
Circuit

Fuse
2.5A

DC 24V
External
Power
supply

+24V

+

-

DIO

LT

Amplifier (DC24V-capable)

Lead wires
from motor

0V

OUT0

OUT3

CW/CCW A

CW/CCW B

Switching A

Switching B

SEE

Advertising