Name and Description
Web Page
Range (Scaling)
Iterations
Default
EIP Decimal (Hex)
Modbus
EIP Data Type
Access
Fixed IP Address
Specify the fixed IP address.
Network Configuration
-2,147,483,647 to
2,147,483,647
-1,062,731,775
Web page only
Web page only
R/W
Fixed Subnet Mask
Specify the fixed subnet mask.
Network Configuration
-2,147,483,647 to
2,147,483,647
-65,536
Web page only
Web page only
R/W
Fixed Gateway
Specify the fixed gateway IP address
Network Configuration
-2,147,483,647 to
2,147,483,647
-1,062,731,775
Web page only
Web page only
R/W
Fixed DNS Server
Specify the fixed DNS server address.
Network Configuration
-2,147,483,647 to
2,147,483,647
-1,062,731,775
Web page only
Web page only
R/W
Device Always Name
Indicates the name with which the controller can
always be accessed via NetBIOS.
PDxxxxxx (last six
digits of serial number)
0
Web page only
Web page only
R
Device Watlow Name
Indicates the controller's Watlow name. The
controller can be browsed using this name.
WATaa:bb:cc (last 3
numbers in MAC
address)
0
Web page only
Web page only
R
Device Configuration > Network > Security
User Name
Enter the User Name for password protection of
the page.
Network Configuration
Monitor Page
Configuration Page
Calibration Page
0
Web page only
Web page only
R/W
Password
Enter the Password for access to the page.
Network Configuration
Monitor Page
Configuration Page
Calibration Page
0
Web page only
Web page only
R/W
Calibration
Save User Settings
Set Yes to save user settings to the EEPROM
Calibration
No (0)
Yes (1)
No (0)
108/1/29 (6C/1/1D)
1061
UINT
R/W
EtherNet/IP Objects
Device Type
Indicates the EtherNet/IP device type for the
controller.
0 to 0
0
1/1/2 (1/1/2)
UINT
R
Identity Object: Product Name
1/1/7 (1/1/7)
SHORT_STRING
R
Identity Object: Serial Number
0 to 2000000200
1/1/6 (1/1/6)
UDINT
R
Identity Object: Status
0 to 0
0
1/1/5 (1/1/5)
WORD
R
Number of O->T Dynamic Assembly Points
0 to 65,535
110/0/100 (6E/0/64)
UINT
R
Number of T->O Dynamic Assembly Points
0 to 65,535
109/0/100 (6D/0/64)
UINT
R
O->T Assembly Size in Bytes
Indicates the size of the O->T assembley.
0 to 65,535
110/0/101 (6E/0/65)
UINT
R
O->T Dynamic Assembly Point {1 to 10}
Read or write the class, instance, and attribute for
each additional O->T assembly point.
0 to 2,147,483,647
0
110/1/1 (6E/1/1)
110/2/1 (6E/2/1)
110/3/1 (6E/3/1)
110/4/1 (6E/4/1)
110/5/1 (6E/5/1)
110/6/1 (6E/6/1)
110/7/1 (6E/7/1)
110/8/1 (6E/8/1)
110/9/1 (6E/9/1)
110/10/1 (6E/A/1)
STRUCT of
USINT[3] (Class,
Instance and
Atttribute)
R/W
Product Code
Indicates the EtherNet/IP product code for the
controller.
200 to 200
200
1/1/3 (1/1/3)
UINT
R
SERIES PD with EtherNet/IP