B1-2, Important, Nyfgw610 vibration criteria – Yokogawa YFGW610 User Manual

Page 21: Nradio device noise to yfgw610

Advertising
background image

<B1. System Installation Specifications>

B1-2

IM 01W02D02-01EN

IMPORTANT

• The temperature specification during operation indicates the criterion of the temperature

at the air intake of the bottom portion of modules. Do not block ventilation holes, as it may

hinder the air-cooling capabilities of the unit. When installing YFGW610 in a cabinet, note

that the temperature specification is not in respect to the ambient temperature of the cabi-

net. Provide cooling fans in the cabinet if needed.

• Avoid exposing YFGW610 to direct sunlight.
• Prevent condensation under any circumstance.
• The dust level of the room should not exceed 0.3 mg/m

3

. Under any circumstance, avoid

iron flakes, carbon particles, or any other type of dust that are conductive.

• Avoid existence of corrosive gases such as hydrogen sulfide, sulfurous acid gas, chlorine,

and ammonia.

n

YFGW610 Vibration Criteria

Ensure that if the frequency of vibration at the installation location is 58 Hz or less, the total

amplitude is maintained less than 0.15 mm. If the vibration frequency is greater than 58 Hz, find

alocation that will meet the following condition:
Acceleration (m/s

2

) = 2π

2

x A x F

2

x 10

-3

< 9.8 (=1G)

where
A : Total amplitude (mm)
F : Frequency (Hz)

The range of allowable total amplitudes is shown below.

10

30

50

70

90

110

130 150Hz

0

0.05

0.1

0.15

0.2

Allowable range

Vibration frequency

mm

Total amplitude

n

Radio Device Noise to YFGW610

The following shows general requirements when using a radio device such as transceivers; how-

ever, as a general rule, close the cabinet door when using a radio device:

• Transceivers that have 3 W of output power or less should be at least 1 m away. Transceiv-

ers that have 10 W of output power or less should be at least 2 m away.

• Radio devices that have 1 W of output power or less including cellular phones and cordless

phones should be at least 1 m away.

• The field wireless device radio output is about 10 mW. There is no impact for YFGW610, but

keep to 1m than the same way as the 1 W output radio device.