2-8

IM 04L61B01-01EN

Displaying Consecutive Data That Exceeds 32 Million Points

Universal Viewer cannot display consecutive data that exceeds 32 million points (e.g., a data

file sampled at 1-second intervals over one year) in the same window.

If you open such data from the search results, the data is automatically divided according to

the following conditions and displayed in multiple windows.

• The first division contains data from the first file up to the file that results in a number of

points as close as possible to, but not exceeding, 32 million points. The number of data

points in this calculation includes those of missing files and those during power-failure

periods.

• In the first division, when the 32 millionth point falls on a power-failure period, the end of

the file before the file containing this power-failure period will be the break point.

• In the second division, the file or the missing file following the first division will be used as

the first file in the division. From this point, the above rule is applied repeatedly.

Note

• The divided pieces of data are displayed in order from the last piece.

• If there is not enough RAM on the PC, a portion of the data may not be displayed.

2.2 Opening a Data File