3.10 Converting Data

You can convert measured data, alarms, and other additional information included in display

and event data files to Excel or ASCII format and save them.

Converting a TLOG file (

section 3.7.2

)

3.10.1 Converting Measured Data

Use the Convert Data dialog box to specify the settings for converting the displayed data.

Procedure

1

In the window, display the file that you want to convert and save.

2

On the

Convert menu, click Data To.

The Convert Data dialog box appears.

3

Specify the settings for the file conversion.

Specify the start and end data numbers.

The timestamps for the start

and end points

Set data sampling.

Range of data

to convert

Click either

group range or

channel range.

Enter the first and last groups.
Enter the first and last channels.

Select whether to include alarm and mark information.

Select the file format.

Specify the file name and

destination.

Number of lines

for dividing

Converted data file name

4

After you finish configuring the settings, click

OK.

The data will be converted.

Explanation

Start and End Points

Specify the range of data to convert.

The range specified by cursors A and B are assigned, respectively, to the start and end

points. If you have not set cursors A and B or have cleared them, the start point data number

will be set to zero, and the end point data number will be set to one less than the total

number of data points.

Step

To keep the data after the conversion from becoming too large, you can sample data.

You can specify sampling in steps. To convert all the data in the specified range, set the step

number to 1.