10 output commands (special response commands), Function via ethernet) -65, App index – Yokogawa Removable Chassis DX1000N User Manual

Page 182

Advertising
background image

3-65

Commands

IM 04L41B01-17E

1

2

3

4

5

6

App

Index

3.10 Output Commands (Special

Response Commands)

*I

Outputs instrument information

Syntax

*I<terminator>

Description This command sends the maker, model, serial

number, and firmware version in a comma-
separated ASCII string with a terminator at the
end.

Example

YOKOGAWA,DX1000,99AA0123,F1.01

3.11 Maintenance and Test

Commands (Available when

using the maintenance/

test server function via

Ethernet)

close Closes another device’s

connection

Syntax

close,p1,p2:p3<terminator>
p1 Port on the DX side (1 to 65535)
p2 IP address on the PC side

(0.0.0.0 to 255.255.255.255)

p3 Port on the PC side (0 to 65535)

Example

close,34159,192.168.111.24:1054

E0

Description You cannot use this command to disconnect a

server port. You cannot use this command to
disconnect from the DX that you are operating.
Use the quit command instead.

con

Outputs connection information

Syntax

con<terminator>

Example

con
EA
00/00/00 12:34:56

Active connections

Proto Local Address Foreign Address State
TCP 192.168.111. 24:34159 192.168.111. 24:1053 ESTABLISHED
TCP 0. 0. 0. 0:34155 0. 0. 0. 0:

0 LISTEN

TCP 0. 0. 0. 0:34159 0. 0. 0. 0:

0 LISTEN

TCP 0. 0. 0. 0:34150 0. 0. 0. 0:

0 LISTEN

EN

TCP
Protocol used.
Local Address
DX socket address.
Displays “IP address:port number.”
Foreign Address
Destination socket address
Displays “IP address:port number.”
State
Connection state.
ESTABLISHED
Connection established.

eth

Outputs Ethernet statistics

Syntax

eth<terminator>

Example

eth
EA
00/00/00 12:34:56

3.10 Output Commands (Special Response Commands) / 3.11 Maintenance and Test Commands

Advertising