3.12 Instrument Information

Output Commands

(Available when using the

instrument information

server function via

Ethernet)

The instrument information server function interprets one
UDP packet to be one command and returns a single packet
(containing DX information) in response to the command.

Port number

34264/udp

Transfer data

ASCII

Receive buffer size

128

Transmit buffer size

512

Maximum number of parameters 32

In the command packet, you arrange the parameters that
correspond to information you want to receive.

Parameter Description
serial

Outputs the serial number.

host

Outputs the host name (host name that you specified in section 1.3).

ip

Outputs the IP address (the IP address that you specified in section
1.3).

Example Query the IP address and host name. (The first

frame below contains the command packet. The
second frame contains the response packet.)

ip host

EA

ip = 192.168.111.24

host = DX1000-1

EN

Description • Separate each parameter with one or more

spaces (space, tab, carriage return, or line
feed).

• Parameters are not case sensitive.
• Undefined parameters are ignored.
• Parameters after the 32nd parameter are

ignored.

3.12 Instrument Information Output Commands