App index – Yokogawa Removable Chassis DX1000N User Manual

Page 239

Advertising
background image

6-13

IM 04L41B01-17E

Specifications

1

2

3

4

5

6

App

Index

Register

Description

Supplementary Information

Type

Access

Simultaneous

Access

Write

Read

409512

Manual sampling start

or other action

Manual sampling: 0. Manual trigger: 1. Snapshot:

2.

INT16

W

410001 to

410002

Batch 1 lot number

Valid range: 0 to 99999999

INT32_L

R/W

410003 to

410020

Batch 1 batch number Up to 18 registers (up to 35 characters with '\0'

termination).
The batch number must be 32 characters or less.

STR36

R/W

410021 to

410050

(Reserved) batch 1

-

-

-

410051 to

410052

Batch 2 lot number

Valid range: 0 to 99999999

INT32_L

R/W

410053 to

410070

Batch 2 batch number Up to 18 registers (up to 35 characters with '\0'

termination).
The batch number must be 32 characters or less.

STR36

R/W

410071 to

410100

(Reserved) batch 2

-

-

-

410101 to

410102

Batch 3 lot number

Valid range: 0 to 99999999

INT32_L

R/W

410103 to

410120

Batch 3 batch number Up to 18 registers (up to 35 characters with '\0'

termination).
The batch number must be 32 characters or less.

STR36

R/W

410121 to

410150

(Reserved) batch 3

-

-

-

410151 to

410152

Batch 4 lot number

Valid range: 0 to 99999999

INT32_L

R/W

410153 to

410170

Batch 4 batch number Up to 18 registers (up to 35 characters with '\0'

termination).
The batch number must be 32 characters or less.

STR36

R/W

410171 to

410200

(Reserved) batch 4

-

-

-

410201 to

410202

Batch 5 lot number

Valid range: 0 to 99999999

INT32_L

R/W

410203 to

410220

Batch 5 batch number Up to 18 registers (up to 35 characters with '\0'

termination).
The batch number must be 32 characters or less.

STR36

R/W

410221 to

410250

(Reserved) batch 5

-

-

-

410251 to

410252

Batch 6 lot number

Valid range: 0 to 99999999

INT32_L

R/W

410253 to

410270

Batch 6 batch number Up to 18 registers (up to 35 characters with '\0'

termination).

The batch number must be 32 characters or less.

STR36

R/W

410271 to

410300

(Reserved) batch 6

-

-

-

410301 to

410302

Batch 7 lot number

Valid range: 0 to 99999999

INT32_L

R/W

410303 to

410320

Batch 7 batch number Up to 18 registers (up to 35 characters with '\0'

termination).
The batch number must be 32 characters or less.

STR36

R/W

410321 to

410350

(Reserved) batch 7

-

-

-

410351 to

410352

Batch 8 lot number

Valid range: 0 to 99999999

INT32_L

R/W

410353 to

410370

Batch 8 batch number Up to 18 registers (up to 35 characters with '\0'

termination).
The batch number must be 32 characters or less.

STR36

R/W

410371 to

410400

(Reserved) batch 8

-

-

-

6.3 Modbus Protocol Specifications