Yokogawa Value Series FX1000 User Manual

Page 17

Advertising
background image

2-8

IM 04L21B01-63EN

Group

A maximum of 50 groups can be set. A maximum of 32 channels can be registered in
one group. Groups are registered when they are recorded on the recorder.

Turn ON/OFF the Display

Check the box of the waveform number to be displayed. Changing this setting will also
change the value of the corresponding waveform display ON/OFF button of the zone
display area of the waveform display window.

Registering the Channel

1. Click one.

2. The [Channel] dialog box opens.

3. Click one.

Types of Y-axis and Turning ON/OFF the Y-axis

Select linear or logarithmic by clicking the Y-axis display area. If you have selected
[Multi-Axis Zone] (see page 2-11, “Setting the Y-axis”), you can set whether to display
the Y axis. The Y-axis of the waveform for which the check box is shown in blue will be
displayed.

Scale (display range)

The range of minimum and maximum values is from -1.0×10

16

to 1.0×10

16

.

Click the scale value display area to enter values.

Zone (display position)

The range is as follows:
• Minimum value: 0 to 99%
• Maximum value: 1 to 100%
Specify the waveform display position by taking the bottom edge of the waveform display
area of the waveform display screen to be 0% and the top edge to be 100%. Click the
zone display area to enter values.

Trip Line

Two trip lines (trip 1 is red, trip 2 is blue) can be set for each channel. Only the trip lines
of the active channel are displayed on the waveform display screen. However, on the
auto zone display screen (see page 2-11, “Setting the Y-axis”), the trip lines of all the
channels are displayed.
In the waveform display area, you can change the positions of the trip lines by dragging
them. In the [General Display Settings] dialog box of the waveform display, click the trip
line value display areas to enter values.

2.2 Displaying the Waveform

Advertising