8 viewing report files, 8 viewing report files -31, Index – Yokogawa Value Series FX1000 User Manual

Page 40

Advertising
background image

2-31

IM 04L21B01-63EN

Displaying Data

1

2

3

Index

2.8 Viewing Report Files

This section explains how to view report files.
Click the [Open] icon on the toolbar, or select [File] - [Open] on the menu bar. In the [Open]
dialog box, select a report file. The report file name extension is .DAR.

Displaying Report Data Values

The following figure is an example in which hourly report and daily report are stored in a
single report file.

Status

The following characters are displayed in Status.

Character String Meaning

Er

A measurement or computation error occurred during the period over which

the report was created.
Note: “Er” is displayed for the following types of channels:

Channels that are set to Log scale (the report computation result will

be an error).
Math channels whose reference channels are set to Log scale (the

computation result will be an error).

Ov

An over range or computation overflow occurred during the period over which

the report was created.

Pw

A power failure occurred during the period over which the report was created.

Cg

The time was changed during the period over which the report was created.

Bo

The burn out occurred during the period for the report.

Advertising