Displaying waveforms of different intervals, Displaying waveforms of different intervals -11, Index – Yokogawa DAQWORX User Manual

Page 47: Dsplayng waveforms of dfferent intervals

Advertising
background image

3-11

IM WX201-01E

Operat

on of the T

rend D

splay W

ndow

1

2

3

4

Index

Tme Axs Dsplay Area

• The time display shows the time of the channel. When the time reference mode

is Start Reference, Trigger Reference, or End Reference, the time of the active

channel is displayed.

• The time display shows the time relative to the start of the waveform display area.

Showng Channel Detals

In the Trend display screen, the information of the active channel is displayed.

Dsplayng Waveforms of Dfferent Intervals

Data of differing measurement intervals can be displayed in the same waveform display

screen.

Measurement Interval of Dsplayed Waveforms

When the measurement intervals differ, the greatest common factor of the

measurement intervals of the channels assigned to the displayed groups is used as
the minimum interval unit for displaying all of the waveforms. In the figure below,
since the intervals for the three channels are 1 s, 500 ms, and 250 ms respectively,

250 ms is used as the interval when all channels are displayed together.

1s

500ms

250ms

250ms

Greatest

common

factor

Dsplayng Waveforms of Intervals Greater Than the Mnmum Unt

If a channel’s interval is longer than the minimum unit interval, data values that are not

measured points are displayed at the value of the points directly thereafter.

Measured point

Measured point

Same value

Same value

Same value Same value

Longer than the minimum unit

interval waveform

Minimum unit interval waveform

Minimum unit display interval

Measured point

The figure below shows a 100 ms and 1 s interval waveform. The waveform with the

long interval is displayed in stages.

Mnmum Unt Interval for Lnked Groups

The greatest common factor of the measurement interval of all channels registered to

all groups belonging to the linked group is used as the minimum unit interval.

3.4 Dsplayng Trends