Chapter 4 troubleshooting, 1 error messages and corrective actions, Search folder registration – Yokogawa DAQWORX User Manual

Page 65: Executing searches, Chapter 4 troubleshootng, 1 error messages and corrective actions -1, Search folder registration -1, Executing searches -1, 1 error messages and correctve actons, Index

Advertising
background image

4-1

IM WX201-01E

T

roubleshoot

ng

1

2

3

4

Index

Chapter 4

Troubleshootng

4.1

Error Messages and Correctve Actons

A message (such as an error message) may appear during operation. The following

describes the meanings of the messages and their corrective actions.

Code

Descrpton

Correctve Acton

E0002

Insufficient memory. Please close at once.

Exit all other software programs and restart the OS.

E0004

Invalid license number.

Reinstall the software.

Please reinstall.

E0101

Please open from the DataBrowser.

This software cannot be opened by itself.
Start it from the DataBrowser.

E4948

Could not initialize communications.

Check whether TCP/IP is operating normally.

M4959

Cannot exit while DataBrowser is starting up.

Close DataBrowser, then shut down or log off.

Search Folder Regstraton

Code

Descrpton

Correctve Acton

E4925

No more search folders can be registered.

The limit of eight folders that can be registered in the
search folder registration area has been reached. If
you need to register a new folder, first delete one or
more of the folders first.

E4940

Same folder ID already exists.

Check the list of registered folders.

A folder with the same ID has already be registered
in the search folder registration dialog box. Either
delete the existing folder from the list, or register the
new folder using a different ID.

E4957

Same folder ID already exists.

Check the search folders.

Same folder ID already exists in the search folder
registration area. Therefore, the new one cannot be
registered. Delete the folder with the same ID from
the registration area, or, register the new folder using
a different ID. If registering with a different ID, use a
folder ID not already listed in the registration area.

E4960

Limit of folders that can be registered exceeded.

If more than two hundred folders would be registered,
registration is denied. If you need to register a new
folder, first delete an existing one from the folder
registration list in the search folder registration dialog
box.

Executng Searches

Code

Descrpton

Correctve Acton

E4907

No response.

Check whether the network is connected correctly
(cables, hubs, and other hardware), and that no
problems occurred on the network.

E4939

Folder ID not found.

On the host on which the error occured, the search
could not be performed because the folder ID does
not exist in the folder registration of the DataBrowser
being run. Register the search folder on the
DataBrowser on the host on which an error occured.

E4942

Folder not found.

Check whether the folder exists on the DataBrowser
on the host on which an error occured.

E4945

Failed to write file.

Failed to write the search results file. Confirm that the
disc capacity and file system are correct.

E4946

Connection failure.

Check whether the host on which an error occured
exists. If it exists, check whether DataBrowser is
running on that host.
Check whether the network is connected correctly
(cables, hubs, and other hardware), and that no
problems occurred on the network.

Advertising
This manual is related to the following products: