Automatic model determination, Scan interval, Setting the number of retries – Yokogawa DAQWORX User Manual

Page 23: Automatic model determination -3, Scan interval -3, Setting the number of retries -3, Index, Automatc model determnaton, Settng the number of retres

Advertising
background image

3-3

IM WX1-03E

1

2

3

Index

Deta

led Descr

pt
on of Funct

ons

Automatc Model Determnaton

If you select a WT and perform automatic model determination, the model and number of

channels are passed to the WT Setting tab on the configurator.

However, harmonic option output for WT1600 and harmonic mode for WT1600 are not

supported.

Models and Number of Channels (Model Name n Brackets)

Model

Number of channels

WT110 [253401]

WT110E [253451]

WT200 [253421]

WT210 [760401]

19

WT130 (2Elements) [253502]

WT230 (2Elements) [760502]

53

WT230 (3Elements) [253503]

WT230 (3Elements) [760503]

70

WT1010 [253610]

WT2010 [253101]

18

WT1030 (2Elements) [253620]

WT2030 (2Elements) [253102]

46

WT1030 (3Elements) [253630]

WT2030 (3Elements) [253103]

61

WT1030M [253640]

68

WT1600 (1Elements) [760101-01/-10]

76

WT1600 (1Elements) [760101-02/-11/-20]

123

WT1600 (1Elements) [760101-03/-12/-21/-30]

170

WT1600 (1Elements) [760101-04/-13/-22/-31/-40]

197

WT1600 (1Elements) [760101-05/-14/-23/-32/-41/-50]

224

WT1600 (1Elements) [760101-06/-15/-24/-33/-42/-51/-60]

251

WT1800 (1Elements) [WT1801-01/-10]

55

WT1800 (2Elements) [WT1802-02/-11/-20]

104

WT1800 (3Elements) [WT1803-03/-12/-21/-30]

104

WT1800 (4Elements) [WT1804-04/-13/-22/-31/-40]

179

WT1800 (5Elements) [WT1805-05/-14/-23/-32/-41/-50]

205

WT1800 (6Elements) [WT1806-06/-15/-24/-33/-42/-51/-60]

254

WT500[1Elements] (760201)

99

WT500[2Elements] (760202)

156

WT500[3Elements] (760203)

213

* The number of WT500 channels given above is with the /G5 and /DS options. If an option

is not installed, the number of channels is decreased by the number of channels related to

that option. The number of WT1800 channels given above is with the /G5 or /G6, /DT, /MTR

or /AUX options. If an option is not installed, the number of channels is decreased by the

number of channels related to that option.

Scan Interval

A scan interval from 0.5 to 3600 seconds is selected for each of the 16 WTs.

Note

When connecting to DAQLOGGER and acquiring data from the WTs, if GateWT’s scan interval

is longer than that of DAQLOGGER, DAQLOGGER logs the same data repeatedly until the

next GateWT scan interval. Therefore, it is recommended that GateWT’s scan interval be set

to a value smaller than DAQLOGGER’s scan interval.

Settng the Number of Retres

The Retry function can be turned ON and OFF for each of the 16 WTs.

If Retry is turned ON, a retry interval of 30 to 3600 seconds can be specified.

Communication is reattempted each time the specified number of seconds elapses.

Retries are also performed on instruments with which a communication error occurred

during the first communication.

3.2 Detaled Descrpton of Functons