3 error messages and corrective actions, Error, Message – Yokogawa DAQWORX User Manual

Page 51: Executable function messages, 3 error messages and corrective actions -31, Error -31, Message -31, Executable function messages -31, 3 error messages and correctve actons, Index

Advertising
background image

3-31

IM WX1-03E

1

2

3

Index

Deta

led Descr

pt
on of Funct

ons

3.3

Error Messages and Correctve Actons

Error

No.

Message

Correctve Actons

E211

Cannot write to file.

Check if the disk capacity is sufficient or if the file systems is
normal.

E212

Cannot read file.

Check if the file exists and is supported by the software or if the
file system is normal.

E213

Cannot open file.

Check if the file exists and is supported by the software or if the
file system is normal

E401

Communication error.

Check if the recorder connected for communication is powered on
and if the cable is properly connected. Also check the following
items according the the communication type.

• For Ethernet

Check if address settings are correct; the TCP/IP protocol is

installed in Windows; the Ethernet card is properly installed.

• For RS-232 and RS-422-A

Check if the baud rate settings match; the port (COM1 to COM9)

settings match, the address settings are correct (RS-422-A); the
serial port of the PC is active and the appropriate cable is being
used.

E402

Communication timeout.

-

E403

Cannot open a communication port.

Same as E401.

E501

Invalid license number.

Please reinstall the software.

Install the software again.

E1010

Execution of aprocess failed.

Check whether an executable function exists, or whether its
files are damaged. If this error appears frequently, reinstall the
software.

E1011

Execuition of a service failed.

Check whether an executable function exists, or whether its
files are damaged. If this error appears frequently, reinstall the
software.

E1600

The WT1000/WT2000 does not support

With WT1000/WT2000 series instruments, model determination
can

Message

No.

Message

M1201

Model determination was successful.

M1210

Setting changes saved before execution.

Executable Functon Messages

No.

Message

Correctve Actons

W[631]

Data Lack

Reduce the number of acquired data points or connected
instruments, or lengthen the scan interval.

E[673]

Cannot open communication

Same as E401.

E[674]

Communication error

Same as E401.

E[675]

Communication time out

Same as E401.

E[850]

Command Error

An error was received from the WT. Check the status of the WT.

E[851]

Cannot setting WT

Check whether the communication status and connected
instruments matches those specified in the software. If they do
not, perform model determination again.

E[852]

Recive Continued

Check the communication status.

E[853]

Recieve data error

Check the communication status.

I[606]

Recovery Communication

Connection recovered.

Advertising