Motor and pulley, All motor data based on standard odp motors – Sterling TC User Manual

Page 11

Advertising
background image

11

IVL44

2.8-3.8

AK51

4.7

Turns Open

IVL34

1.9-2.9

AL64

6.0

AL74

7.0

AL84

8.0

AK56

5.2

AL104

10.0

MOTOR PULLEYS

BLOWER PULLEYS

Pulley Table 1725 RPM Motors (1/3 to 2 H.P.)

327
345
362
380
397
414
431
448
466
483
500
518
535
552
569
587
604
621
638
656

410
431
453
474
496
517
539
560
582
604
625
647
668
690
712
733
755
776
798
819

468
493
517
542
567
591
616
641
665
690
715
739
764
789
813
838
863
887
912
936

546
575
603
633
661
690
719
748
776
805
834
863
891
920
949
978

1006
1035
1064
1093

630
663
697
730
763
796
829
863
896
928
962
995

1028
1061
1094
1127
1161
1194
1227
1260

697
734
771
807
844
880
918
954
991

1027
1064
1101
1137
1174
1211
1247
1284
1321
1357
1394

5
4-1/2
4
3-1/2
3
2-1/2
2
1-1/2
1
1/2
0

5
4-1/2
4
3-1/2
3
2-1/2
2
1-1/2
1
1/2
0

MOTOR AND PULLEY

All motor data based on standard ODP Motors.

Table 6

Table 5

Motor Full Load Amps*

VOLTAGE - PHASE

HP

115-1

208-1

230-1

208-3

230-3

460-3

575-3

1/4

5.1

2.2

2.3

1.7

1.3

0.7

N/A

1/2

7.2

3.7

3.8

2.3

2.2

1.1

0.8

3/4

11.6

5.2

5.0

3.0

3.4

1.7

1.1

1

13.0

6.6

6.5

3.4

3.4

1.7

1.3

1-1/2

18.2

9.1

9.1

5.1

5.2

2.6

1.7

2

21.0

11.3

10.5

6.2

6.0

3.0

N/A

* Average value, all speeds and frequencies.