Sterling TC User Manual

Page 2

Advertising
background image

2

TABLE OF CONTENTS

The following terms are used throughout this manual, in addition to the ETL requirements to bring attention to the
presence of potential hazards, or to important information concerning the product:

Indicates an imminently hazardous

situation which, if not avoided, will result in
death, serious injury, or substantial property
damage.

Indicates an imminently hazard-

ous situation which, if not avoided, could result
in death, serious injury, or substantial property
damage.

Indicates an imminently hazardous

situation which, if not avoided, may result in minor
injury or property damage.

NOTICE: Used to notify of special instructions on
installation, operation, or maintenance which are
important to equipment but not related to personal
injury.

DESCRIPTION………………. ....................................... 2
GENERAL SAFETY INFORMATION
Installation Codes………………………………… 2, 3
Special Precautions………………………………. 2, 3
PERFORMANCE AND DIMENSIONAL DATA .............. 4
INSTALLATION
Locating Units………………………………………… 5
Combustion Air……………………………………… . 5
Heat Throw Data……………………………………. . 6
Clearances…………………………………….. ......... 7
Suspension of Units………………………………. .... 7
Gas Piping……………………………………… ........ 8
Pipe Installation……………………………………. ... 9
BLOWER SET UP AND ADJUSTMENT……………... 10

MOTOR AND PULLEY .............................................. 11
ELECTRICAL CONNECTIONS…………………. ...12-16
VENTING ..............................................................17-21
OPERATION
Explanation of Controls…………………………… . 22
Start-Up, Shut Down………………......…………....22
Main Burner Orifi ce Schedule…………….……….23
Gas Input Rate and Adjustments…………….. 23, 24
TROUBLESHOOTING GUIDE ..............................25-28

LED Indicator Troubleshooting .............................. 29

MAINTENANCE… ...................................................... 30
WARRANTY…............................................................ 31
IDENTIFICATION OF PARTS ................................32-33
UNIT NUMBER DESCRIPTION ................................. 35
START-UP INSPECTION SHEET ............................... 36

NOTICE: It is the equipment owners responsibility to provide any scaffolding or other apparatus required to
perform emergency service or annual/periodic maintenance to this equipment.

DESCRIPTION

The Power Vented Gas Fired Blower Unit Heaters are
factory assembled, high static pressure type, centrifugal
blower units designed for heavy duty applications such
as continuous operation or where a single unit heater
must do the entire heating job in a large area.These
blower type unit heaters may be used with the standard
adjustable louvers, with short duct runs or discharge

nozzles for spot heating. These blower type unit heaters
may be used where low sound levels are required. The
designs are certified by ETL as providing a minimum
of 83% thermal efficiency, and approved for use in
California. Do not alter these units in any way. If you
have any questions after reading this manual, contact
the manufacturer.

Figure 1 - Tubular Blower Unit Heater

See Identifi cation of Parts, Figures 12 through 18.

Advertising