TUBULAR BLOWER

UNIT NUMBER DESCRIPTION

Digit #1, 2 - Unit Type [UT]

TC - Tubular Blower

Digit #3, 4, 5 - Capacity [CA]

100 - 100,000 BTU/HR
125 - 125,000 BTU/HR
150 - 150,000 BTU/HR
175 - 175,000 BTU/HR
200 - 200,000 BTU/HR
250 - 250,000 BTU/HR
300 - 300,000 BTU/HR
350 - 350,000 BTU/HR
400 - 400,000 BTU/HR

Digit #6 - Furnace Type [FT]

A - Right Side Access

Digit #7 - Heat Exchanger Construction Material [FM]

1 - Standard (Aluminized) Steel
2 - 409 Stainless Steel

Digit #8 - Gas Type [GT]

N - Natural Gas
P - Propane Gas (LP)

Digit #9 - Ignition Control [IC]

S - 0-4,999 ft.
T - 5,000-11,999 ft.
Note: Installations over 2,000 ft. require gas input deration in the fi eld.
Refer to unit installation instructions.

Digit #10 - Direct Spark Gas Control [GC]

1 - Single Stage
2 - Two Stage
3 - Electronic Modulation w/Room Sensing
4 - Electronic Modulation w/Duct Sensing
5 - Electronic Modulation w/Duct Sensing & Room Ovrd. Stat
6 - Electronic Modulation w/External 4-20 mA Input
7 - Electronic Modulation w/External 0-10 VDC Input

Digit #11 - Supply Voltage [SV]

1 - 115/1/60 5

- 230/3/60

2 - 208/1/60 6

- 460/3/60

3 - 230/1/60 7

- 575/3/60

4 - 208/3/60

Z - Special

Note: Supply Voltages [SV] 2-7 include factory mounted step down transformer.

Digit #12 - Motor Type [MT]

1 - Open Drip Proof (Standard)
2 - Totally Enclosed
3 - Premium Effi ciency, Open Drip Proof
4 - Premium Effi ciency, Totally Enclosed

Digit #13 - Blower Motor Sizes [MS]**

A - 1/4 HP w/Contactor

P - 1/2 HP w/Magnetic Starter

C - 1/2 HP w/Contactor

R - 3/4 HP w/Magnetic Starter

D - 3/4 HP w/Contactor

S - 1 HP w/Magnetic Starter

F - 1 HP w/Contactor

T - 1-1/2 HP w/Magnetic Starter

G - 1-1/2 HP w/Contactor

U - 2 HP w/Magnetic Starter

H - 2 HP w/Contactor

W - 1/4 HP w/Magnetic Starter

J - 1/4 HP

0 - None/Not Applicable

L - 1/2 HP
**Notes: 1. All 3-phase units [SV = 4, 5, 6, 7] include a contactor as standard.
2. All single phase units [SV = 1, 2, 3] include a contactor for units equipped with
3/4 HP. motor or higher [MS = D, F, G, H]
3. [MS] options J, L only available with [SV] option 1 (115/1/60).

Digit #14 - Accessories [AS]

FACTORY INSTALLED

M8 - Discharge Duct Flange

S3 - 409 Stainless Steel Flue Collector

S5 - 304L Stainless Steel Burners

P4 - Terminal Block Wiring

P6 - Summer/Winter Switch

† FIELD INSTALLED (AS-____ )

† Field Installed Accessories are not included in the Unit Number. All Field Installed
Accessories are entered as a separate line item using the catalog number which utilizes
“AS” as a prefi x. i.e: A7 becomes AS-A7.

A7 - Pressure Regulator 1/2-2 psi

M2-2 - Vent Caps (5 inch) (Unit Capacity 100-250)

M2-3 - Vent Caps (6 inch) (Unit Capacity 300-400)

F1 - 1-Stage T675A Ductstat
F2
- 2-Stage T678A Ductstat

P5 - 24V SPST Relay-Specify Purpose


G1 - 1-Stage T87K Mercury Free Thermostat

X2 - 30 Degree Downturn Nozzle

w/Subbase Kit

X3 - 60 Degree Downturn Nozzle

G2 - 1-Stage T87K Mercury Free Thermostat

X4 - 90 Degree Downturn Nozzle

w/TG511A Guard Kit

X5 - Vertical Louver Kit

G3 - 1-Stage T834N Mercury Free Thermostat

w/Fan Switch
G5 - 2-Stage TH5220D Mercury Free Thermostat
w/Subbase
G6 - Locking Thermostat Cover
G8
- 1-Stage T6169C Line Voltage Stat
w/Subbase
G9 - 1-Stage T822K Mercury Free Thermostat



Digit

X X X X — 1 2 3 4 5 6 7 8 9 10

11

12

13

14 +