Maintenance, Troubleshooting – UView MiST In-Car Air Quality System User Manual

Page 12

Advertising
background image

Maintenance

Upper Grill & Fan:

The upper fan may build

up residue and stick after extended use. This is

normal. Spray lightly with water or gently rotate fan

to free up mechanism.

DO NOT USE WATER ON lOWER GRIll & FAN!
lower Grill & Fan:

White dust may appear on the

lower grill. This is normal. Brush or blow dust off

DO NOT USE WATER

. Water will damage

internal electrical components behind the lower grill & fan

and void warranty!

Troubleshooting

RED lIGHT DOES NOT TURN ON:

check the vehicle’s 12V Dc receptacle fuse.

check the fuse in the MiST™ connector (See MiST™ FUSE bLOWN below). If both

are OK, clean out the connectors and try again. The unit will not work with voltage

under 11.5V Dc. Ensure the vehicle is running and the A/c is “ON”. Verify the voltage

with a volt meter. If the 12V DC connection supplies erratic or too little voltage, an

optional extension cord (sold separately) is available to connect to the vehicle’s

battery. If voltage is correct, proceed by pushing down the red start button. The solid

green light should come on and the unit should begin to mist. This confirms that the

unit is functioning properly and the red light is defective. If there is no green light and

the unit still will not function cALL cUSTOMER SERVIcE.

MiST™ FUSE blOWN:

Replace the standard fuse (10 amp) inside the 12V DC

adapter of the MiST™ unit by unscrewing the end. Ensure vehicle is running and A/C

is “ON” to provide proper power levels to the MiST™ unit.

GREEN lIGHT IS blINKING QUICKlY:

This is a trouble code signaling that the

MiST unit is receiving a lower voltage than the 11.5V DC. Clean receptacle and

check the vehicle’s charging system, it may be fluctuating lower than the 11.5V Dc

required. If that is the case, connect directly to the vehicle’s battery with the optional

extension cord (sold separately). Ensure that the vehicle is running and the A/C is

“ON” to provide proper power levels to the MiST™ unit. If this doesn’t work cALL

CUSTOMER SERVICE.

RESTARTING THE UNIT:

Power must be disconnected to clear the unit’s

code by disconnecting and reconnecting the 12V DC adapter. Be sure to check the

fluid level before restarting.

RED AND GREEN lIGHTS ARE ON (SOlID) AND THE MiST™ UNIT IS NOT

MISTING:

Shut the unit off and check the fluid levels to ensure it is above the

minimum level, then restart and allow the unit to operate for a few minutes and check

that the upper fan is operating. (See maintenance at the top of this page.) If the unit

still produces no mist cALL cUSTOMER SERVIcE. If the unit was running empty

(without fluid) then the piezos have burned out. This is NOT covered under warranty!

Upper Grill & Fan

lower Grill & Fan

– 11 –