42
Brocade VDX 6730 Hardware Reference Manual
53-1002389-06
Replacing a power supply FRU in a Brocade VDX 6730-76
5
FIGURE 15
Orientation of the DC power supply and fan assembly in the Brocade VDX 6730-32
5. Verify that the power supply and fan assembly status LED is steady green to indicate normal
operation (see
for more LED information).
You can display the power supply and fan assembly status using the following commands from
the CLI:
•
show system
•
show environment fan
•
show environment power
Replacing a power supply FRU in a Brocade VDX 6730-76
The Brocade VDX 6730-76 has two power supplies, as displayed in
. The Network OS
identifies the power supplies from left to right on the non-port side as power supply #2 and power
supply #1.
1
Brocade VDX 6730-243254 chassis
3
Label with part number
2
DC power supply and fan assembly
4
Captive screw
P/N: xxxxxxx-xx
3
4
1
2
1