Brocade VDX 6730 Hardware Reference Manual

45

53-1002389-06

Replacing a power supply FRU in a Brocade VDX 6730-76

5

FIGURE 17

Inserting the power supply in the Brocade VDX 6730-76

7. Plug the power cord into the power supply to power on the unit.

The power supply will immediately attempt to power up.

CAUTION

If you observe that the switch has powered down approximately two minutes after a power supply
replacement, it is likely because the new power supply has a mismatched airflow. Check your
console for error messages.

8. Verify that the LED on the new power supply displays steady green while the Brocade VDX

6730-76 is operating (see

Table 7

). If the LED is not steady green, ensure that the power

supply is securely installed and seated properly.

You can enter one of the following commands at the command line prompt to display the power
supply status:

show chassis

show environment power

Advertising