Cabling infrastructure

Ensure that the proper cabling is installed at the site. For information about supported SFP and SFP+
transceivers and cable lengths and types, refer to the following Brocade website:

http://www.brocade.com/downloads/documents/data_sheets/product_data_sheets/Optics_DS.pdf

Installation location

Devices can be mounted in a standard 19-inch equipment rack, on a flat surface, on a wall, or on a
metal surface.

The site should meet the following requirements:

•

Maintain the operating environment as specified in the section

Environmental considerations

on

page 42.

•

Allow a minimum of 7.62 cm (3 in.) of space above the device and between the front and the back
of the device and walls or other obstructions for proper airflow.

•

Allow at least 7.62 cm (3 in.) of space at the front and back of the device for the twisted-pair, fiber-
optic, and power cabling.

•

The site should be accessible for installing, cabling and maintaining the devices.

•

Allow the status LEDs to be clearly visible.

•

Allow for twisted-pair cables to be routed away from power lines, fluorescent lighting fixtures, and
other sources of electrical interference, such as radios and transmitters.

•

Allow for the unit to be connected to a separate grounded power outlet that provides 100 to 240
VAC, 50 to 60 Hz, is within 2 m (6.6 ft) of each device, and is powered from an independent circuit
breaker. As with any equipment, a filter or surge suppressor is recommended.

•

For a 2-post rail mount configuration, order the appropriate mounting kit and refer to the kit
documentation.

•

When using the magnet mount installation to install the device on a metal surface, the device
cannot be installed above 1.9 meters.

Rack-mount installation considerations

Before mounting the device in a rack, ensure that the following rack-mount installation requirements
are met:

•

Allow a minimum of 7.62 cm (3 in.) of space above the device and between the front and the back
of the device and walls or other obstructions for proper airflow.

•

Temperature: Because the temperature within a rack assembly may be higher than the ambient
room temperature, check that the rack-environment temperature is within the specified operating
temperature range. (Refer to

Operating environment

on page 42.)

•

Mechanical loading: Do not place any equipment on top of a rack-mounted unit.

•

Circuit overloading: Be sure that the supply circuit to the rack assembly is not overloaded.

•

Grounding: Rack-mounted equipment should be properly grounded.

Installing the device

You can install the device on a desktop, an equipment rack, a wall, or on a metal surface:

Cabling infrastructure

20

Brocade ICX 6430-C Compact Switch Hardware Installation Guide