INSTALLATION STEP

Material required for a drilled well application

Tools
Screwdrivers, hacksaw to cut pipe, knife to assist in pipe cutting, round file to smooth pipe ends, pipe
wrench, adjustable wrench to tighten fittings, propane torch and welding material.

Deep well pump
 Desired length of polyethylene 1” pipe, 100 PSI,

CSA or UL approved to link up from pumping
level to pump.

 1 Poly rope
 Well seal (150156).
 Pitless adaptor (150155).
 1” male brass adaptors (750871).
 1” stainless steel clamps (750885).
 Electrical tape.
 Teflon tape.
 Pressure relief valve 1/2” NPT.
 Torque arrestor (150158)

Tank installation
 Desired length of 1” braided hose (750919) to

link up from pump to tank. Keep tank as close
as possible to the pump.

 1 Tank “T” (650651).
 1 1/2” Drain valve (650659).
1 1/2” Safety valve (150162).
 2 1” Female adaptor(750949).
 1 1” Galvanized or brass elbow.
 Pressure gauge (750769).
L.O.P. pressure switch (150159S).
 1/4” X 3” Galvanized or brass nipple
 Teflon tape.

Information regarding your well may be obtained from your well Driller’s log.

If no information is available, you can determine the depth of the well by lowering a heavy
(small) weight tied to a long cord or fishing line. Lower the weight to the well bottom, take
up the slack, and mark line where it meets the top of the well. Remove the weight from the
well and measure line to determine well depth. Repeat the operation with a dry cord. Mark
the line at the top of the well and where it become wet. You now know where is the water
level.

Please remember, a submersible pump should not be lower than 10 feet from the
bottom of the well and no higher than 10 feet below the water level.

If you are replacing your old pump with a new pump of similar horsepower and capacity,
install the new pump at the same level in the well. If a new pump is larger in horsepower
(ie: replacing a 1/2 Hp with a 3/4 Hp) or if the pumping capacity is higher (ie: providing
7gpm instead of 5 gpm), set the pump deeper in the well provided that the well will support
the additional volume.