Step 9 step 7 step 8 – Burcam 105 Series Submersible Deep Well Pumps or SUB-PACS v.2 User Manual

Page 7

Advertising
background image

7

Roll out the submersible pump cable on the ground along side of your 1” plastic Poly pipe.
At 5 foot intervals, using your electrical tape, tape the cable to the pipe. This will prevent the
cable from hitting the well casing when lowering pump into the well.

Securely attach your 1/4’’ poly safety rope to the lug provided on the discharge end of your
submersible pump. (see picture 1 below) When lowered, this rope should be long enough to reach
the pump setting in your well. As a precaution, the other end of the safety rope should be attached
to a pipe of one or two feet in length (galvanized steel) so that should the pump be dropped in the
well, while being lowered, the pipe will stop the loss of the safety rope by the pipe coming to rest
across the diameter of the well casing.

With the aide of your helper, it is now time to lower pump and piping
assembly into your well casing. Following this operation, fix
the safety rope to an anchor on the side of the well casing. Install the
well cap and fix it after carely placing the power cables and
the safety rope in the appropriate opening. You can now attach the
power cables to the pipe in the trench, using electric tape. Align
the pipe and the power cables in the trench, from the well to the
basement wall. Make sure the length of pipe and power cables is
long enough inside the basement to reach the tank position. Prior to
fill the trench, test the whole system.

STEP 9

STEP 7

STEP 8

WELL

SEAL150156

PITLESS

ADAPTOR

150155

STAINLESS

STELL

CLAMP

750885

1”BRONZE

ADAPTOR

750871

TORQUE

ARRESTOR

150158

1” BRONZE

ADAPTOR

750871

ELECTRICAL

SUBMERSIBLE

CABLE

150192ST

NYLON

CABLE

PUMP

MOTOR

1” PIPE

Picture #2

Picture #3

Picture #1

Advertising