APPLICATION

This pump is designed for shallow well

installation for a suction level up to 25 feet.

Capacity at 20 PSI :

5’

900 US GPH

10’

750 US GPH

15’

640 US GPH

20’

560 US GPH

25’

475 US GPH

FEATURES

304 stainless steel pump body, easy to prime.

Totally enclosed, fan cooled motor,

bearing to bearing. Built for a continuous use.

Full time connected run capacitor, to eliminate

starting wear vs regular motor.

Thermal and overload protection.

Noryl impeller, built-in injector

3/4HP, 115/230V AC, 60Hz, 9A, (18A when start).

STEP 1

FRICTION LOSS IN PIPE

NOT INCLUDED

INSTALLATION STEPS

NEVER RUN THE PUMP DRY

3

We recommend that you install your pump in a clean and dry location where there is adequate room

for servicing at a later date. Protection from freezing temperatures and good ventilation should be

considered as well, to provide the pump an environment for long life. Locating the pump as close as

possible to the water source will reduce friction losses encountered in the suction pipe.

Friction losses in the suction pipe must be taken into consideration when the horizontal offset is greater

than 50 feet. The suction pipes should be increased from 1” to 1 1/4”. This will reduce friction losses and

allow the pump to give

maximum performance.

A new well should be checked to determine that it is free from sand. Sand will damage the seal and the

impeller. Have your well driller clean the well before your installation.

Never run the pump dry. Damage to the seal may occur. Fill pump body and suction pipe with water

before turning on the power.

THE RUN OF HORIZONTAL PIPE FROM THE TOP OF YOUR WELL

INTO THE HOUSE, WHERE YOUR PUMP WILL BE LOCATED, MUST BE

INSTALLED IN A TRENCH, BELOW THE FROST LEVEL OF YOUR AREA.