ELECTRICAL INSTALLATION

We recommend that a licensed electrician be employed to do wiring to the pressure switch.

Permanently ground the motor in accordance to the electrical codes for your area.

Do not use an extension cord to connect your pump to the power source. From your

distribution panel to the pressure switch, we recommend a wire gauge not smaller than 14

gauge.

Pressure switch setting (start/stop 20/40 or 30/50) has been made in factory. An adjustment

may be done to give other operating pressures.

Adjustment or modification of start/stop setting of pressure switch have to be done carefully.

Turn adjustment nut half turn at a time.

Turn nut 1 clockwise to raise start and stop pressure setting.

Never turn nut 2. This will

change the 20 PSI range between start and stop pressure and may damage your tank’s

bladder or modify the efficiency of your water system. Check system operation after each

adjustment.

STEP 10

Electrical line

from home

distribution

panel.

BLACK

RED

GREEN

GROUND

TO MOTOR LEAD

VOLTAGE SELECTION SWITCH

1.POWER off

2. Please SELECT the up knob

position for 115 V or down knob

position for 230 V.

3. CONNECT to the appropriate

power source.