5.2 Orientation of terminal box (see

FIG. 4)

If necessary, the orientation of the motor,

and with it that of the terminal box, can be

changed.

- Remove the motor attachment screws

and turn the motor to the desired

position.

Take care not to damage the

casing gasket, and reinstall it

correctly.

The terminal box should not be

placed at 3 and 6 o’clock on an

cold water circuit.

5.3 Electrical connection

The electrical connect must be

made by a qualified electrician

and comply with applicable local

standards.

Complete electrical information about the

circulator is given on the data plate.

Power supply network

Use a three-conductor cable (3 x

1.5mm

2

) to connect mains power to the

corresponding terminals of the circulator;

phase (L), neutral (N), and earth ( ) (see

FIG. 5).

The power cable must not touch

the pipe or the pump; make sure

that it is away from any moisture.

Check line protection and the mains

voltage and frequency. The circulator

must be connected to the mains via a

switch with an opening distance, on

each pole, of at least 3mm. The motors

of the circulator models SC & SB are

self protected by impedance, therefore

they don’t need external protection. The

motors of the circulators SS need a

contactor with overload fitted. The power

outlet must have an earthing contact.

After making the connections, put the

cover back on the terminal box.

6.

STARTING UP

6.1 Filling, degassing

Never operate the circulator

WITHOUT WATER

- Open the valves on both sides of

the circulator and fill the installation

completely.

- Bleed the circuit at the high point.

- Bleed air from the circuit, by hand, by

unscrewing the plug (see FIG. 6) a few

turns; close it when water runs out and

when there are no more air bubbles.

Risks of scald. Use a

screwdriver for unscrewing

the tap.

- Power up the motor to start the

circulator.

- The flow rate is adjusted by changing

the speed of rotation of the motor using

the selector switch.

Risk of burning. In

operation, the motor casing

may be hotter than 100

o

C.

7. SERVICING

The circulator needs no special servicing

in operation. The motor bearings are

lubricated by the liquid pumped.

At the beginning of each heating season,

or after a prolonged shutdown, make sure

that the circulator turns freely.

8.

OPERATING TROUBLE

Causes and remedies

Switch the circulator OFF

before doing any work on

it.

~ 6 ~