0 safety, 0 safety • safety labels and locations, F/n: llv3ep8 – Hired-Hand Universal Ray Tube Heaters: AG2 Series Rev.11-07 User Manual

Page 3: F/n: llv3ep1, 120v

Advertising
background image

1.0

Safety

Manifold Pressure

Max. Inlet Pressure

Min. Inlet Pressure for
Purpose of Input Adjustment

Min. Mounting Angle

Max. Mounting Angle

Combustion Chamber

W.C.P.

W.C.P.

W.C.P.

5.0in.

14.0in.

3.5in.

0 DEGREES

45 DEGREES

4” BC Aluminized

120V

4.8

1.1

C1

VOLTS AC 60Hz

AMPS - Starting

AMPS - Running

Heater Type:

DESIGN COMPLIES WITH:

ANSI Z83.20b-2003-GAS FIRED LOW INTENSITY INFRA-RED HTR.

For Stainless Steel Upgrades the Combustion Table is upgraded to 409 Stainless Steel

Serial No. 0603DETR12345 0001

DETROIT RADIANT PRODUCTS CO.
21400 HOOVER ROAD - WARREN, MI 48089
(586) 756-0950 www.reverberray.com

AG2 - 40 - 125N

MODEL NO.

125,000 / 95,000

INPUT BTU/H

NAT GAS

FOR USE WITH

RE-VERBER-RAY INFRA-RED RADIANT TUBE HEATER

FOR INDOOR INSTALLATION ONLY

DO NOT

AIR

METERING

ORIFICE

REMOVE

NEUTRAL

EARTH

HOT

- 120V HEATER INPUT -

120V

AIR 

METERING 

ORIFICE

DO NOT 

REMOVE

Manifold Pressure

Max. Inlet Pressure

Min. Inlet Pressure for
Purpose of Input Adjustment

Min. Mounting Angle

Max. Mounting Angle

Combustion Chamber

W.C.P.

W.C.P.

W.C.P.

5.0in.

14.0in.

3.5in.

0 DEGREES

45 DEGREES

4” BC Aluminized

120V

4.8

1.1

C1

VOLTS AC 60Hz

AMPS - Starting

AMPS - Running

Heater Type:

DESIGN COMPLIES WITH:

ANS Z83.20b-2003-GAS FIRED LOW INTENSITY INFRA-RED HTR.

For Stainless Steel Upgrades the Combustion Table is upgraded to 409 Stainless Steel

Serial No. 0603DETR12345 0001

DETROIT RADIANT PRODUCTS CO.
21400 HOOVER ROAD - WARREN, MI 48089
(586) 756-0950 www.reverberray.com

AG2 - 40 - 125N

MODEL NO.

125,000 / 95,000

INPUT BTU/H

NAT GAS

FOR USE WITH

RE-VERBER-RAY INFRA-RED RADIANT TUBE HEATER

FOR INDOOR INSTALLATION ONLY

Gas Valve:
Circuit Board:
Wire Harness:
N.O. Switch:
N.O. VL Orifice:
N.C. Switch:
N.C. VL Orifice:
Diff Switch:
Diff VL Orifice:
Igniter:
Burner:
16” Tube:
Ind Lights:
Diag Light:
Term Block:
Transfomer:
Fan:
Alternate Fan:
Alt. Fan Usage:

IS22016051F5169 264E

36E96-224-N
Micro60-24

840
851

3 PCS Harness

852

None

N/A

None
None

N/A

None

Grey (+/-)
Norton

50

High

201

4” Stnd.

202

Yellow - 24V

828

Red LED

827

None

N/A

40VA

826

Fasco Lg.

55A

50Hz - 120V

55B

When Specified

BURNER COMPNENTS (Specify TP - #’s)

Your Heater is: C1

Orifice Type
Gas: TP204-#
Air: TP44-#

C1

C2

C3

3

3

1

1 1/2” 1 5/8” 1 5/8”

Relay:
Filter:
24 Volt In:
120 Volt In:

None

N/A

None
3T - plug

832

2x4 Box

Gas In:
Extra VL Orifice:

7/8” FC Flare

83

None

N/A

66

TUBE COMBINATION / KIT PARTS

Combustion:
Radiant:
Clamp:
Hangers:
RCS:
Reflector:
Endcap:
Baffle:

ID:
Electric:
Special 1:
Special 2:
Tag:

For Internal Use Only

TP-26A
TP-26A
TP-21B
TP-19B
TP-82
TP-20C
TP-105
TP-651 - 4”R

TP-26E
TP-26D
TP-21O
TP-19B-SS
TP-82-SS
TP-20C-SS
TP-105-SS

Item

Standard

Stainless Steel

Re-Verber-Ray
LLWT38
Micro60
Plug-Wh.
None

For all

Standard

Labels

See Board

Contact factory at 586-756-0950 for parts information and list prices. Or visit
http://wwwreverberray.com/parts

Data on this label is for the model shown on this label. If your heater has been
converted, this information is not correct. Please contact the factory for assistance.

RVA2-40-125N

Production Code: RVA2-125
Version: 8/06

0603DETR12345 0001

Serial #:

N/A

Stock:

None

Add-On Option(s):

SA

MP

LE

SA

MP

LE

Safety Labels and Their Locations

1.0

Safety • Safety Labels and Locations

Read and understand all safety information and warnings in this insert manual and the
Tube Heater General Manual before installation, operation and maintenance of the
radiant tube heater system.

Back Panel

Top Panel

AG2

Series

Rating Plate

F/N: LLTB018 (Natural Gas)

F/N: LLTB019 (LP Gas)

F/N: LLTB008

F/N: LLTCL001 Clearance to

Combustibles Label

3

Burner Control Box

Component Label (located

under the top panel)

Product safety signs or labels should be replaced by the product user when they no longer are legible.
Contact either your local distributor or the product manufacturer for obtaining replacement signs or labels.

24V

24V IN

NEUTRAL

- 24V HEATER INPUT -

F/N: LLV3EP8

NEUTRAL

EARTH

HOT

- 120V HEATER INPUT -

120V

F/N: LLV3EP1

Advertising