Installer, F/n: lltb004, F/n: llv2ep9 – Hired-Hand Universal Ray Tube Heaters: AG2 Series Rev.11-07 User Manual

Page 4

Advertising
background image

LED CODE

FAULT STATUS

FAULT CODE DELAY

Initial flash on power up,

then steady off

Normal operation

Immediate

Steady on

Module failure / Internal fault

Immediate

1 flash

Ignition failure

30-32 minutes

2 or 3 flashes

APS - Note: fan / intake / exhaust

10-12 minutes

4 flashes

Solenoid valve fault / Leaky valve /

Flame amplifier fault

Immediate

No flash on 117V start up

Transformer fault

Immediate

!

CAUTION

Provide 24

Volts Only

This heater has a 24 Volt

control system. Do not

connect 120 Volt power

supply, as it will damage

the controls.

LED CODE

FAULT STATUS

FAULT CODE DELAY

Initial flash on power up, 

then steady off

Normal operation

Immediate

Steady on

Module failure / Internal fault

Immediate

1 flash

Ignition failure

30-32 minutes

2 or 3 flashes

APS - Note: fan / intake / exhaust

10-12 minutes

4 flashes

Solenoid valve fault / Leaky valve / 

Flame amplifier fault

Immediate

No flash on 117V start up

Transformer fault

Immediate

This heater is equipped with an
HLRB (Relay Board) required for
grouping multiple heaters on the

same thermostat. This heater must be wired
with a field supplied transformer in accordance
with the installation, operation manual.

AVOID EQUIPMENT FAILURE

THIS 10 FT. TUBE IS THE

COMBUSTION CHAMBER.

THIS TUBE MUST BE THE FIRST TUBE

FOLLOWING THE BURNER CONTROL BOX.

!

INSTALLER

The combustion chamber utilizes either 409

stainless, titanium alloy or aluminized steel -

depending on the model number of your heater.

Rotate the tube’s welded seam to bottom.

Consult the manual(s) for further details.

4

1.0

Safety • Safety Labels and Locations • Clearance to Combustibles

F/N: LLTP031 (This label is located on

models with a relay board installed only.)

AG2

Series

F/N: LLTB007(2)

F/N: LLDR003

(This label is

located on models

with a relay board

installed only).

SERVICE ACCESS PANEL

IGNITER & FLAME SENSE COMPARTMENT

1. Turn off gas & electricity.

2. Remove cover by lifting top

cover upward and outward.

CAUTION: HOT SURFACE.

KEEP COVER IN PLACE. REMOVE FOR SERVICE ONLY.

SERVICE ACCESS PANEL

IGNITER & FLAME SENSE COMPARTMENT

1. Turn off gas & electricity.

2. Remove cover by lifting top

cover upward and outward.

CAUTION: HOT SURFACE.

KEEP COVER IN PLACE. REMOVE FOR SERVICE ONLY.

INSTALLER

***AVOID EQUIPMENT FAILURE***

THIS 10’ TUBE IS THE

COMBUSTION CHAMBER.

THE COMUSTION CHAMBER UTILIZES

EITHER 409 STAINLESS TITANIUM OR ALUMINIZED

STEEL - DEPENDING UPON THE

MODEL NUMBER OF YOUR HEATER

THIS TUBE MUST BE THE FIRST TUBE

FOLLOWING THE BURNER BOX.

MOUNT WELDED SEAM TO BOTTOM

CONSULT IOM OR PACKAGING STICKER FOR DETAILS

F/N: LLTB004

(orange)

F/N: LLTB026

Right Panel

(Valve Compartment)

Radiant

Tube

Primary Combustion

Chamber

16” Burner Tube

Left Panel

(Fan Compartment)

!

CAUTION

Provide 24

Volts Only

This heater has a 24 Volt

control system. Do not

connect 120 Volt power

supply, as it will damage

the controls.

F/N: LL01 - Clearance Safety Tag

(Affix adjacent to heater’s thermostat)

HIGH

FIRE

H

L

LOW

FIRE

F/N: LLV2EP9