7 connecting ac power, Terminal strip inside heat zone controller, 240 volt source – Hired-Hand Farm Hand Series: Heat Zone User Manual

Page 18: 120 volt source

Advertising
background image

Part No. 4801-5129 rev 6-04

Farm Hand Heat Zone

16

9.7

Connecting AC Power













































To Breaker

Terminal Strip inside Heat Zone Controller

GROUND

HOT

NEUTRAL

240 Volt Source

To Breaker

Terminal Strip inside Heat Zone Controller

GROUND

HOT

NEUTRA
L

120 Volt Source

Power Supply

Stage 1

Stage 2

Stage 3

Stage 4

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

120V

(L2)

Hot

(L1)

240V

(L2)

L1 L2

GND

L1 L2

L1 L2 L1 L2

Power Supply

Stage 1

Stage 2

Stage 3

Stage 4

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

120V

(L2)

Hot

(L1)

240V

(L2)

L1 L2

GND

L1 L2

L1 L2 L1 L2