INSTALLATION

MObIFLEX 200-M

A-6

INSTALLING THE LAMP OPTIONS
AND ARC SENSOR

(continued)

MAKING THE CONNECTIONS AT THE HOOD
Feed the 13 ft. connecting cable through the hole in
the hood (Fig. 10, Item B).

Have a qualified electrician connect the 13 ft. connect-
ing cable leads, lamp leads, and sensor leads (if
used) to the control board (Fig. 11, Item B). Push the
board onto the bottom of the remote switch (Fig. 11,
Item C). Snap the switch box into place atop the hood.

ELECTRICAL INSTALLATION

Connect the Mobiflex 200-M to 115VAC single phase,
grounded receptacle suitable for 15 amp service.