Installation, Installing the lamp options and arc sensor, Warning – Lincoln Electric IM621 Mobiflex 200-M K1653-1,-2 User Manual

Page 15: Fig. 14, Fig. 15

Advertising
background image

A-8

INSTALLATION

MObIFLEX 200-M

A-8

INSTALLING THE LAMP OPTIONS
AND ARC SENSOR

(continued)

Loosen the four screws of the cover, lift the cover
around the arm and turn it 180 degrees, and allow it to
rest on the filter cover. Remove the control cover (Fig.
14, Item A), secured by four screws as shown. Route
the 13 ft. connecting cable through the grommet in the
control cover (cut an X as before).

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts such

as internal wiring.

• Turn the input power off at the fuse box

before working on this equipment.

• Have a qualified person install and ser-

vice this equipment.

------------------------------------------------------------------------

MOUNTING THE TRANSFORMER RELAY KIT
(K1653-1 Mobiflex 200-M only)
When installing a K1653-1 Mobiflex 200-M with a
K1669-1 or K1669-3 Lamp Kit:

Note: If the control panel has the Contactor,
Transformer, Fuseblock/Fuse, and Terminal Blo ck
already installed (as in Fig. 15), skip to the next step
“Making the connections at the Control Panel.”

Use the seven supplied screws to mount the pieces of
the Transformer Relay Kit in the Control Panel of the
Mobiflex unit as shown in Figure 15. Use the two
smaller screws to mount the terminal block (E), one of
the larger screws to mount the fuse holder (C), and
the four remaining large screws to mount the trans-
former (B).

Mount the Contactor (A) on the DIN rail next to the
Starter/Overload. The mounting points have been
marked on the mounting surface of the control panel.

Have a qualified electrician make the connections
according to the wiring diagram in the back of this
manual. Reference wiring diagrams for “K1653-1
Mobiflex 200-M” and “Mobiflex 200-M with Lamp
Option and Arc Sensor” in the back of this manual.

Note: The (2) fan motor wires must be moved from
the top of the Starter/OL to the bottom of the
Contactor. Reference the wiring diagram in the back
of this manual for details.

Loop any extra cable inside the control box. Replace
the control cover and large cover over the handles.

MAKING CONNECTIONS AT THE CONTROL PANEL
(K1653-2 Mobiflex 200-M with Transformer only)
When installing a K1653-2 Mobiflex 200-M with a
K1706-series Work Lamp:

Note: To insert conductors in Terminal Block, push in
on front opening with small screwdriver, and insert
conductor into corresponding top opening.

Note: GN is not the same potential as Ground.

Remove the jumper on the terminal block. Connect
the leads of the 13 ft. connecting cable according to
color (WH, BN, GN). Loop any extra cable inside the
control box. Replace the control cover and large cover
over the handles.

A

B

Client: Lincoln/Euromate

Client no/project no: 123380/170922

Date: 07.08.1997

Drawing no/archive no:linTR101.eps

Version no:1

Illustrator: Jos Taabe

Description:

demontage kap/paneel.

A

B

Client: Lincoln/Euromate

Client no/project no: 123380/170922

Date: 07.08.1997

Drawing no/archive no:linTR101.eps

Version no:1

Illustrator: Jos Taabe

Description:

demontage kap/paneel.

Fig. 14

A

B

C

D

E

Fuse

Terminal Block

Fuse Holder

Contactor

Starter/OL

Transformer

A

B

C

D

E

Fuse

Terminal Block

Fuse Holder

Contactor

Starter/OL

Transformer

Fig. 15

WARNING