Installation, Safety precautions, General description – Lincoln Electric IM621 Mobiflex 200-M K1653-1,-2 User Manual

Page 9: Warning

Advertising
background image

This device automatically switches the Mobiflex unit
on when it senses a welding arc, and off when it does
not sense the arc.

This manual covers installation of a
K1653-1 or K1653-2 Mobiflex 200-M

with a K1655-1 LFA 3.1, 10 ft. Arm

or a K1655-2 LFA 4.1, 13 ft. Arm

This manual also covers installation of
the appropriate optional Lamp Kit:

On a K1653-1 Mobiflex 200-M: a K1669-1 Lamp Kit

or K1669-3 Lamp Kit with Arc Sensor

On a K1653-2 Mobiflex 200-M: a K1706-1 Work Lamp

or K1706-2 Work Lamp with Arc Sensor.

Instructions are also included to install
the optional K1670-1 Arc Sensor

in either

the K1669-1 Lamp Kit or K1706-1 Work Lamp.

Note: The K1706-1 and K1706-2 Work Lamp options
cannot be combined with a K1653-1 Mobiflex 200-M.

This installation section covers the following
machines:
K1653-1 Mobiflex 200-M
K1653-2 Mobiflex 200-M with Transformer Relay Kit
This installation section covers any of the following
accessories as installed on the above machines:
K1655-1 LFA 3.1, 10 ft. Arm
K1655-2 LFA 4.1, 13 ft. Arm
K1669-1 Lamp Kit for K1653-1 Mobiflex 200-M
K1669-3 Lamp Kit with Arc Sensor for K1653-1
K1706-1 Work Lamp for K1653-2 Mobiflex 200-M
K1706-2 Work Lamp with Arc Sensor for K1653-2
K1670-1 Arc Sensor

The K1653-1 Mobiflex 200-M includes:
• Mobile base unit
• Flexible hose for connecting the extraction arm

The K1653-2 Mobiflex 200-M includes:
• Mobile base unit
• Flexible hose for connecting the extraction arm
• Factory-installed Transformer Relay Kit

The LFA 3.1 or 4.1 extraction arm includes:
• Assembled arm, 2 sections
• Flexible hose, (2) 8” Rubber seals for hood hinge
• Hood assembly
• (2) Bolts, M8x1.25, 45mm long (about 1.75”)
• (2) Nuts, M8 self-locking
• Hose running guard
• Clamping pin for red plastic ring
• Metal rotating hinge
• Red plastic ring

A-2

INSTALLATION

MObIFLEX 200-M

A-2

Read this entire installation section before you
start installation.

SAFETY PRECAUTIONS

Do not attempt to use this equipment until you have
thoroughly read all installation, operating and mainte-
nance information supplied with your equipment. They
include important safety precautions and detailed
operating and maintenance instructions.

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts such

as internal wiring.

• Turn the input power off at the fuse box

before working on this equipment.

• Have a qualified person install and ser-

vice this equipment.

------------------------------------------------------------------------

MOVING PARTS can injure.

• Do not operate without extraction arm

installed.

• Keep away from moving parts.

------------------------------------------------------------------------

Only qualified personnel should install, use or service
this equipment.

GENERAL DESCRIPTION

The Mobiflex 200-M is a self-contained system for the
removal and filtration of welding fume particles and
other particulate. It is a low vacuum, high volume sys-
tem that uses a spring balanced, articulated arm to
provide localized ventilation for welding or other appli-
cations. With large rear wheels and front casters, it is
suitable for use in relatively small workshops or on
mobile fume sources. A wheel locking mechanism
provides stability while positioning the arm. The
Mobiflex 200-M is suitable for light duty, intermittent
use. It has an 18 ft. (6 m) input cord with a standard
115VAC, 1ph, 60Hz plug. The filter system features a
spark arrester and a square, disposable paper filter
cartridge with a filtering efficiency of 99.8%. Fume is
captured on the inside of the cartridge, keeping hands
clean during filter maintenance.

The Mobiflex 200-M can be used with either a
10 ft. or 13 ft. extraction arm. The hood of the arm can
be retrofitted with a 24VAC lamp kit with remote,
hood-mounted switch for the blower. An automatic
start/stop arc sensor is also available for use with the
lamp kit.

WARNING

Advertising