A-2

INSTALLATION

POWER FEED

®

10M SINGLE WIRE FEEDER

A-2

SAFETY PRECAUTION

LOCATION

• The POWER FEED

®

10M Single Wire Feeder has

an IP21 rating, suitable for indoor use.

• The POWER FEED

®

10M Single Wire Feeder

should be operated in a substantially upright posi-
tion.

• Do not submerge the POWER FEED

®

10M Single

Wire Feeder.

• The POWER FEED

®

10M Single Wire Feeder is not

suitable for stacking.

Locate the POWER FEED

®

10M Single Wire Feeder

away from radio controlled machinery. The normal
operation of the POWER FEED

®

10M Single Wire

Feeder may adversely affect the operation of RF con-
trolled equipment, which may result in bodily injury or
damage to the equipment.

ELECTRIC SHOCK can kill.

• Only qualified personnel should

perform this installation.

• Turn off the input power to the

power source at the disconnect
switch or fuse box before working
on this equipment. Turn off the
input power to any other equipment
connected to the welding system at
the disconnect switch or fuse box
before working on this equipment.

• Do not touch electrically hot parts.

----------------------------------------------------------------------------------------

FIGURE A.1

MOUNTING

Wire Drive Mounting (See Figure A.1)

The wire drive may be mounted by using the four
holes on the bottom. Because the feed plate and
gearbox are electrically "hot" when welding, make cer-
tain the parts do not contact the any structure or per-
son.

Mount the wire drive with the drive rolls in the vertical
plane to prevent dirt from collecting in the wire drive.
Angle the drive and feed plate to prevent sharp bends
in the gun and cable and incoming wire.

WELD CABLE SIZING

Minimum work and electrode cables sizes are as follows:

TABLE A.1

(Current (60% Duty Cycle) MINIMUM COPPER

WORK CABLE SIZE AWG
Up To-100 Ft. Length (30 m)

400 Amps

2/0 (67 mm2)

500 Amps

3/0 (85 mm2)

600 Amps

3/0 (85 mm2)

WELD CABLE CONNECTION

Connect a work lead of sufficient size and length (Per
Table A.1) between the proper output terminal on the
power source and the work. Be sure the connection to
the work makes tight metal-to-metal electrical contact.
To avoid interference problems with other equipment
and to achieve the best possible operation, route all
cables directly to the work or wire feeder. Avoid
excessive lengths and do not coil excess cable.

When using an inverter type power source like the
Power Waves

®

, use the largest welding (electrode

and work) cables that are practical. At least 2/0
copper wire - even if the average output current
would not normally require it. When pulsing, the
pulse current can reach very high levels. Voltage
drops can become excessive, leading to poor
welding characteristics, if undersized welding
cables are used.

------------------------------------------------------------------------

For Electrode

Connect the

Connect the

Polarity:

Electrode lead to

work lead to

Positive

Positive Stud

Negative

Negative

Negative Stud

Positive Stud

For additional Safety information regarding the elec-
trode and work cable set-up, See the standard "SAFE-
TY INFORMATION" located in the front of the
Instruction Manuals.

CAUTION